AMBIENT GROUP
Dioxins/Furans, HRGC/HRMS (8290)
CUent Sample ED: 211909-05D
Lot-Sample G2D190191 - 005 Work Order#-.: EX6VG1AA Matrix—: SOLID
Date Sampled...! 04/18/02 Date Received..: 04/19/02 Instrument: 5D5
Prep Date......; 04/19/02 Atsiysis Date-: 04/24/02 Units--.; pg/g
Prep Batch 2109509 Dilution Factor: 1 % Moisture:
DETECTION TEE TEQ
UMIT FACTOR CONCENTRATION
PARAMETER RESULT
23.7,8-TCDD 390 1.000 390.000000
1.23,7,8-PeCDD 1200 0.500 600.000000
133.4,7,8-HxCDD 1200 0.100 120.000000
1,23,6,7,8-HxCDD 2400 0.100 240.000000
133,7,8,9-HxCDD 1800 0.100 180.000000
133,4,6,7,8-HpCDD 14000 0.010 140.000000
OCDD 27000 0.001 27.000000
23,7,8-TCDF 2500 CON 0.100 250.000000
133,7,8-PeCDF 3500 0.050 180.000000
23,4,7,8-PeCDF 5500 0.500 2,800.000000
133,4,7,8-HxCDF 6000 0.100 600.000000
133,6,7,8-HxCDF 5400 0.100 540.000000
23,4,6,7,8-HxCDF 5800 0.100 580.000000
133,7,8.9-HxCDF 440 0.100 44.000000
133,4,6,7,8-HpCDr 26000 0.010 260.000000
133,4,7,8,9-HpCDF 3000 0.010 30.000000
OCDF 23000 0.001 23.000000
Total TEQ Concentration 7,004.000000
PERCENT RECOVERY
INTERNAL STANDARDS RECOVERY LIMITS
13C-23,7.8-TCDD 62 40.135
13C-133.7,8-PeCDD 61 40-135
13C-13,3,6,7.8-HxCDD 57 40 -135
13C-l,2,3,4,6,7,8-HpCDD 76 40 -135
13C-OCDD 97 40 -135
13C-2,3,7,8-TCDF 66 40 -135
13C-1,2,3,7,8-PeCDF 71 40 -135
13C-1,2,3,4,7,8-HxCDF 70 40 -135
13C-l,2,3.4,6,7,8-HpCDF 98 40 -135
Notes:
TEF values are cited in U.S. Environmental Protection Agency, (1989) Interim procedures for estimating risks assodated with exposures to mixtures ofchlorinated
(CDDs and CDPs) and 1989 update. U.S. Environmental Protcoion Agency, Risk Assessment forum, Washington, DC;
CON Confirmation analysis.
Sac.Sffld.IEQJUT fUr.O ll/IOZ200(
CITY_21MC100_009100067