NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Bulk sample analysis report, NYC-DCAS

Machine-extracted title · confidence 66%

Bulk sample analysis for DCAS project; multiple lab IDs and floor locations listed.

NYC-WTC_000266326–000266328
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMt/VNdUU/UIIO 35-« 36th Street Long Island City New York, 11106 Tel: (718 729-1997 Fax: 718 729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: HEALTH DEPT. - 125 Worth Stieet, Manhattan, NY PROJECT#: Client Sample ID^ : 6 7 8 9 10 Lab Sample ID=/ ■ 010917D-882 010917D-883 010917D-884 010917D-885 010917D-886 Sample Location. 7th Floor 3rd Floor 3rd Floor 3rd Floor Ground Floor Window Sill Stair "A" West Stair "D" East Elevator Lobby South Entrance Elevator Looby Window Sill North Homogeneity Yes Ires Yes Yes Yes Sample Description Sill Floor Floor Sill Floor Wipe W ipe Wipe Wipe Wipe

Color BIk BIk Blk BIk Blk Texture Mixed Mixed Mixed Mixed Mixed Sample Treatment. None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr Mat (Type & Percent)- 5%SYNTH 10%SYNTH 10%SYNTH 5%SYNTH 25%SYNTH 2%CELL 5%CELL 2%CELL 10%CELL 8%CELL Non Fibr Mat <1%FBGL (Percent) 92% 85% 88% 85% 67% Date Received: 9/17/01 Date of Analysis 9/17/01 Date of Report 9/17/01

Analyst; Lab Managef: Roodv Itouis David Chen ' * Analysis of samples is performed by^Polanzed Light Micro .copv (PLM) - Point Counting Method (EPA 600/M4-82-02O) * Analytical equipments Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsem ;nt by NVLAP or any agency of the US Government i\YS-DOH ELAP #11273 NIST-N^LAP # 192047 AIHA ft: 100269

CITY_21MC100_002777677

NYC-WTC_000266327

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266327Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000268267

Bulk sample analysis report for NYC-DCAS at Health Dept. building 125; Lab Sample IDs listed.

Similar indexed content

Compare copies and versions →