Asbestos in air analysis report, WTC site

Machine-extracted title · confidence 55%

Asbestos air analysis report for WTC site tents and areas, NY.

NYC-WTC_000265813–000265815
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTS 35 4036111 Stmt Lorg Island City NewYork, 11106 Tel: (710)729-1907 ANALYSIS REPORT Fax:(718)729-1576 ASBESTOS IN AIR Tranamtefain Electron MicroicoDv

CLIENT: NYC-DDC PROJECT ADDRESS: WTC Site -130 Cedar Street, Manhattan - NY - Tents 1,4,7,9 - South Wall, Tents 2.5,8,11 - Bathroom, Tents J, 6,9,12 - North Wall PROJECT; WTC - Gap Clean Up WOLK: 454(-KAM-AS17- Lab ID# Client Semple Locaiion Volume Grid Total Area Filter Analytical Asbestos Asbestos Structures Detected Structure Structure Sample (liters) Openings Analyzed Area Sensitivity Typc(s) (microns) Density Concentration ID# Examined (mm’) (mra’t (struct/cc air) (stnK/mm’) (slnidcc) O.5-3.O >5.0 Toul Total

110680-12 12 IWA - 7th Floor Tent K6 North 1290 6 0.06 .385 0.0050 ND 0 0 0 <1667 <0.0050 Wall - South 110680-13 13 IWA - 6th Floor Tent 117 South 1290 6 0.06 385 00050 ND 0 0 0 <16.67 <0.0050 Wall - North 110680-14 14 IWA - 6tli Floor Tent K7 South 1290 6 0.06 385 0.0050 ND 0 0 0 <16.67 <0.0050 Wall - West 110680-15 15 IWA - 6th Root Tent K8 1290 6 0.06 385 0.0050 ND 0 0 0 <16.67 <0.0050 Bathroom - North 110680-16 16 IWA -6th Root Tent #8 1290 6 0.06 385 0.0050 ND 0 0 0 <16.67 <0.0050 Bathroom - West 110680-17 17 IWA - 6th Floor Tent #9 North 1290 6 0.06 385 0.0050 ND 0 0 0 <16.67 <0.0050 Wall-North 110680-18 18 IWA - 6th Floor Tent #9 North 1290 6 0.06 385 0.0050 ND 0 0 0 <16.67 <0.0050 Wall - South 110680-19 19 IWA - 5th Root Tent KI0 South 1290 6 0.06 385 0.0050 ND 0 0 0 <16.67 <0,0050 Wall - North 110680-20 20 IWA - 5th Floor Tent # 10 South 1290 6 0.06 385 0.0050 ND 0 0 0 <16.67 <0.0050 Q Wall - West 110680-21 21 IWA - 5tli Root Tent KI 1 1290 6 0.06 385 0.0050 ND 0 0 0 <16.67 <0.0050 o Bathroom - North m 110680-22 22 IWA-5th Floor Tent #11 1290 6 0.06 385 0.0050 ND 0 0 0 <16.67 <0 0050 Bathroom - West § o Grid Opening Area: 0.010 mm' Date Received: 05/18/08 20 Date Collected: 05/17/08 Date Analyzed; 05/18/08 CD Date of Report: 05/19/08 Anaivst: A- Lab Dlrecter; o AlaxBmngolts Kouvaras > z z •Sample Com&tioo upon receipt: Acceptable > * Accuracy of atulysu: RP[X).36 •Analyhcal Quality Cootrcl Requiremenu were met for this set of sampler •Ana^a performed according 1© AH ERA Method (EPA 40 CFR Part 763 - Appeodix A).Sampkj will be stored for ninety (90) day* and dien retumad to tbedieat upon mpert W LaborafOfy mtur report as verifiable oaJy operatzou and asafym pert Ifa filler with fetidue was received fiam nan’Ubanttxy pnsonael c tbea Che bborateny report tfcouki report aa vcrifuble only the Btructurct / car* CD 1"° AIHAK: 100169 NIST-NVLAPd : 102047 NVS-DOH ELAP#; 11273 o o o Page 2 of 3 O O

NYC-WTC_000265814

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000265814Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000208985

Analysis report from KAM Consultants regarding asbestos levels in air at Stuyvesant High School using transmission electron microscopy.

Similar indexed content

NYC-WTC_000208975

Analysis report from KAM Consultants regarding asbestos levels in air at Stuyvesant High School for the Department of Design and Construction.

Similar indexed content

Compare copies and versions →