NYC-WTC_000369025
Pre-bid meeting notice and background for 125 Cedar Street cleaning.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Meeting notice and follow-up on cleanup at 125 Cedar Street, monitoring.
NYC-WTC_000265486–000265490OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Asbestos Air Moiiitoriim
1 Al a minimum, five (5) TEM samples shall be collected per day during cleanup activities
2. Samples shall be collected at isolation barriers outside the work area, the clean room of the worker/wasie decontamination facility, and outside of the building.
3. Sample collection during clean up activities shall be in accordance with Title 15, Chapter 1 of the Rules of the City of New York (RCNY) and AHERA regarding documentation, sample locations, rate of flow, and required volumes to achieve the necessary analytical sensitivity.
4 Sampling equipment shall be placed at representative locations and away from obstruction. Sampling cassette must be placed on a tripod and not taped to existing surfaces. All air sampling equipment shall be pre- and post- calibrated to insure accurate air sampling volumes.
5 The Air Sampling Technician shall perform clearance air sampling after the areas are free of dust accumulations as deiermined by the Project Monitor. All surfaces must be completely dry prior to the start of sampling. Clearance air sampling shall be performed at each apartment. Five samples shall be collected in each apartment and two samples shall be collected in each common space. The eievaior shaft and first tloor commercial spaces shall be cleared separately. Clearance air monitoring shall be performed after the completion of all clean up activities at the work site. Clearance air sampling shall be aggressive and performed in accordance with Title 15, Chapter 1 of the RCNY Section 1-43 (a)-(d)
0. Clearance air samples shall be collected m accordance with the procedures specified in itie NIOSH 7400 Method The tlow rale for collection of air samples shall be at least 10 liters per minute and no more than 15 liters per minute. Air sampling cassettes must be monitored to ensure the filters do not develop dark spots that would indicate clogging. The minimum sampling volume is 3600 liters. If clogging develops, the cassette must be changed.
7 All clearance air samples and conipleied chain of custody forms must be transported to the laboratory immediately after sampling is completed
Clearance Criteria
1 The following clearance levels have been established by the USEPA for clean up activities resulting from the collapse of the W'l'C.
I ^^uruHieter Clearance Level __________________ ! Asbestos in air 0 0009 f/cc PCMe Primary cleaiaiice ievel Lead in settled dust <25 pg/ft^_______ ^2 Primary clearance level Dioxin in settled dust <4ng/m^ __________ Primary clearance level l-'.ljiutis glass in air <0.01 f/cc___________ Secondary clearance level Crystalline silica in air C5pg/m’ __________ Secondary clearance level PAHs in settled dust <0.3 mg/m^ Secondary clearance level Mercury between 1 and 2 mg/m^ Secondary clearance level
4 of 5
CITY_21MC100_0 09369221
NYC-WTC_000265489
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000369025
Pre-bid meeting notice and background for 125 Cedar Street cleaning.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000284079
Mandatory pre-bid and monitoring scope for asbestos abatement and air monitoring at 125 Cedar Street.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369016
Pre-bid meeting details for asbestos air monitoring at 125 Cedar Street.
14 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369010
Chain-of-custody style memo describing asbestos air monitoring and building scope.
14 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000416644
Pre-bid meeting and scope for environmental monitoring during interior cleaning.
14 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000430503
Plan and responsibilities for on-site asbestos air monitoring and debris cleanup.
14 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000267357
Mandatory pre-bid meeting notice for WTC UNA scope at 125 Cedar Street.
12 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452652
DEP scope of work for on-site asbestos air monitoring at 125 Cedar Street.
14 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444855
Procurement and scope document for asbestos air monitoring at 125 Cedar Street.
14 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446586
Chain-of-custody document detailing asbestos sample monitoring setup for 125 Cedar Street decontamination.
14 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435590
DEP memo outlining pre-bid meeting and asbestos monitoring for WTC renovation.
14 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195796
Document outlining requirements for a pre-bid conference regarding asbestos abatement and air monitoring at a World Trade Center facility.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000107393
Document defining the scope for environmental monitoring, sampling, and asbestos air monitoring at 125 Cedar Street.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107393
Document defining the scope for environmental monitoring, sampling, and asbestos air monitoring at 125 Cedar Street.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107379
Detailed scope of work document for DEP-contracted asbestos abatement and cleaning of the interior of 125 Cedar Street.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369025
Pre-bid meeting notice and background for 125 Cedar Street cleaning.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000284079
Mandatory pre-bid and monitoring scope for asbestos abatement and air monitoring at 125 Cedar Street.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279016
Mandatory meeting notice for WTC-related remediation, site walk-through scheduled.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000369025
Pre-bid meeting notice and background for 125 Cedar Street cleaning.
Similar indexed content
NYC-WTC_000195796
Document outlining requirements for a pre-bid conference regarding asbestos abatement and air monitoring at a World Trade Center facility.
Similar indexed content
NYC-WTC_000284079
Mandatory pre-bid and monitoring scope for asbestos abatement and air monitoring at 125 Cedar Street.
Similar indexed content
NYC-WTC_000369016
Pre-bid meeting details for asbestos air monitoring at 125 Cedar Street.
Similar indexed content
NYC-WTC_000369010
Chain-of-custody style memo describing asbestos air monitoring and building scope.
Similar indexed content