NYC-WTC_000262546
TEM analysis of air samples at New Stuyvesant High School exterior/interior for AHERA, received 03/14/02.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗TEM air sample analyses for AHERA clearance at New Stuyvesant High School exterior/interior (03/12/02).
NYC-WTC_000262488–000262516OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Associates 104 East 25 Street, New York, NY 10010 Phone: (212) 353-8280 Fax: (212) 353-8306
Attn: Mr. Bernard Orlan Received: 3/12/02 9:00:00 PM N.Y.C. Board of Education ATC Group#: 7046 28-11 Queens Plaza North Analysis Date: 3/12/02 Long Island City, NY 11101 Fax: (212) 475-4122 Phone: (212)477-8941 Proj ect: New Stuyvesant H. S. , 345 Chambers St., NY , NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Volume Analyzed Asb Type(s) O.Sft-5 5fi (S/cc) (S/mm^) (S/cc) Notes
1 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7046 -I
2 1928.00 0.0450 0 None Detected 0 0 0.0044 < 22.24 <0.0044 7046 -2
3 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7046 -3
4 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7046 -4
5 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7046 -5
6 1944.00 0.0450 O’ None Detected 0 0 0.0044 <22.24 <0.0044 7046 -6
' 7 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7046 -7
MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: A™roved^by:
Disclaimer The laboratory is not responsible for data reported in structuresTcc, which is dependent on volume collected by non-laboratory personnel. This lab s only responsible । for data reported in stnjctures/mm’ This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim i product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95% i confidence limits and laboratory and analysis' accuracy and precision) is available upon request
Accredited for NVLAP PLM/TEM #101187-0, NY State ElAP #10879
Page 1 of 3
CONFIDENTIAL, CITY_21MC100_003466681 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000262489
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000262546
TEM analysis of air samples at New Stuyvesant High School exterior/interior for AHERA, received 03/14/02.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262401
TEM analysis results of air samples from New Stuyvesant High School exterior/interior areas.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262517
TEM analysis of air samples at New Stuyvesant High School exterior/interior for AHERA, received 03/13/02.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261474
TEM results for air samples at New Stuyvesant High School, exterior/interior, Feb 2002.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261937
TEM analysis results of air samples from New Stuyvesant High School exterior/interior areas.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261706
TEM results for air samples at New Stuyvesant High School, exterior/interior, Feb 2002.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262024
TEM analysis results of air samples from New Stuyvesant High School exterior/interior areas.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261648
TEM results for air samples at New Stuyvesant High School, exterior/interior, Feb 2002.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261763
TEM results for air samples at New Stuyvesant High School, exterior/interior, Feb 2002.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261879
TEM analysis results of air samples from New Stuyvesant High School, exterior and interior areas.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262575
TEM analysis of air samples at New Stuyvesant High School exterior/interior for AHERA, received 03/16/02.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261821
TEM results for air samples at New Stuyvesant High School, exterior/interior, Feb 2002.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis of air samples at New Stuyvesant High School exterior/interior for AHERA, received 03/14/02.
Similar indexed content
TEM analysis results of air samples from New Stuyvesant High School exterior/interior areas.
Similar indexed content
TEM analysis of air samples at New Stuyvesant High School exterior/interior for AHERA, received 03/13/02.
Similar indexed content
TEM results for air samples at New Stuyvesant High School, exterior/interior, Feb 2002.
Similar indexed content
TEM analysis results of air samples from New Stuyvesant High School exterior/interior areas.
Similar indexed content