NYC-WTC_000260582
TEM analysis results for air samples from New Stuyvesant H.S., 12/31/01 data documented.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Chain-of-custody TEM analysis results for air samples at New Stuyvesant High School, Jan 2002.
NYC-WTC_000261300–000261328OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet I Client Name: NYC BOB Volume (liters): 1952 Lab Group #: 6464 Filter Type Filter Area: MCE 385 mm^ Lab Sample #: 10 Grid Opening Size: 0.01124 Client Sample #: ;o Area Examined: 0.04496 mnr
GRID BOX: 7-4/) Magnification: 20,000 GRID ID: Accelerating Voltage: 100 KeV # Grid Openings; 4 Analysis Date: 1/27/02
Analysis Performed By: ROMAN PEYSAKHOV
SO, Structure | Structure Type Length ID of Structure N or V EDE No Nonadb F B ’ C M >=05 p >=5p Chrys Amphiboie Ncnasfc Ambig/ND No Coord Elements) I I ------------ 1 /
J__ , : i I 1
Struct = > 0,5p > 5:1 Aspoct Ratio Grid acceptance: •y'= Positive ditfradion pattern properties conforming to <50% undissoived filter, overlapped or folded Totals laboratoy ideritification criteria observed <10% particulate coverage >50% coverage ate
2= EDS spectrum conforming to laOorator)' least 20 unfoldsd or overlapped grid squares <5% notes or opaque areas F p I C j M >5p
identifiestion criteria observed Chrysotile AMPHIBOLES Amphibole F = Single Fioei Amosite B = Bundle (<3 fibers <1 liber diameter apart Crocidolite Ambiguous C = Cluster (>3 Interseclionsi Anthophyllite Non-Asbestos M = Malrx Tramolite Actinolite NoD-Identified NSC = No Structures Detected
CITY_21MC100_003465418 CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000261313
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000260582
TEM analysis results for air samples from New Stuyvesant H.S., 12/31/01 data documented.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261387
TEM analysis results for air samples at New Stuyvesant High School, exterior/interior, Jan 2002.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260640
TEM analysis results for air samples at New Stuyvesant H.S., 12/31/01 data documented.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260698
TEM analysis results for air samples at New Stuyvesant H.S., 12/31/01 data documented.
17 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261416
TEM results for air samples at New Stuyvesant High School, exterior/interior, Jan 2002.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261075
TEM results for air samples from exterior and interior of New Stuyvesant High School.
16 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260843
TEM results for air samples at exterior and interior of New Stuyvesant High School.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260814
TEM results for air samples collected at New Stuyvesant High School exterior/interior areas.
16 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261162
TEM results for air samples collected at exterior and interior of New Stuyvesant High School.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260930
TEM results for air samples from exterior and interior of New Stuyvesant High School.
16 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261046
TEM results for air samples collected at exterior and interior of New Stuyvesant High School.
16 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260669
TEM analysis results for air samples at New Stuyvesant H.S., 12/31/01 data documented.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000392959
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000198416
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237069
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000223895
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261242
TEM results for air samples from exterior and interior of New Stuyvesant High School.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260959
TEM analysis of air samples from New Stuyvesant High School exterior/interior areas.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis results for air samples from New Stuyvesant H.S., 12/31/01 data documented.
Similar indexed content
TEM analysis results for air samples at New Stuyvesant High School, exterior/interior, Jan 2002.
Similar indexed content
TEM analysis results for air samples at New Stuyvesant H.S., 12/31/01 data documented.
Similar indexed content
TEM analysis results for air samples at New Stuyvesant H.S., 12/31/01 data documented.
Similar indexed content
TEM results for air samples at New Stuyvesant High School, exterior/interior, Jan 2002.
Similar indexed content