NYC-WTC_000260582
TEM analysis results for air samples from New Stuyvesant H.S., 12/31/01 data documented.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗TEM results for air samples collected at exterior and interior of New Stuyvesant High School.
NYC-WTC_000261271–000261299OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet Client Name: NYC BOE Volume (liters): 1952 Lab Group 6454 Filter Type / Filter Area: MCE 385 mm’ Lab Sample #: 10 Grid Opening Size: 0.01124 Client Sample #: 10 Area Examined: 0.04496 mm’
GRID BOX: Magnification: 20 000 GRID ED: .Accelerating Voltage: 100 KeV # Grid Openings: 4 Analysis Date: 1,'26/02 i Analysis Performed By: MARK PEYSAKHOV
GO structure i Structure Type Length ID of Structure Nor 7 EDS I No I F I B ' C I M (Nonadb ) >=05 y Chrys Amphibole Nonaso I Amcig/ND Elements) j No Coora <5|J -------- ------------ -------- 1-------- ___ -J
I ! t I Struct = > 0.5p > 5; 1 Aspect Ratio Grid acceptance: '1= “ositive diffraction pattern properties conforming :o <50% undissolved filter, overlaoped or folded Totals iabcratory identification criteria observed <10% particulate coverage >50% coverage ate least 20 unfolded or overlapped grid squares <5% F B C M >5u 'J = tDS spearjm conforming to laboratory holes or opaque areas identification critena observec Chrysotile AMPHIBOLES Amphibole r = Single Fiber Amosite B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos Tremolite M = Matrix Non-Identified j Actinolite Mtn = .sin Structures Detected
CONFIDENTIAL, CITY_21MC100_003465389 SUBJECT TO PROTECTIVE ORDER NO, 2, SEPT. 2008
NYC-WTC_000261284
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000260582
TEM analysis results for air samples from New Stuyvesant H.S., 12/31/01 data documented.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260553
TEM analysis results for air samples from New Stuyvesant H.S. exterior/interior, 12/31/01.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260872
TEM analysis of air samples from New Stuyvesant High School exterior/interior areas.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260640
TEM analysis results for air samples at New Stuyvesant H.S., 12/31/01 data documented.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261162
TEM results for air samples collected at exterior and interior of New Stuyvesant High School.
16 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260988
TEM results for air samples at exterior and interior of New Stuyvesant High School.
17 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260814
TEM results for air samples collected at New Stuyvesant High School exterior/interior areas.
16 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261242
TEM results for air samples from exterior and interior of New Stuyvesant High School.
17 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261213
TEM results for air samples at exterior and interior of New Stuyvesant High School.
17 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260843
TEM results for air samples at exterior and interior of New Stuyvesant High School.
16 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260669
TEM analysis results for air samples at New Stuyvesant H.S., 12/31/01 data documented.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261561
TEM analysis results for air samples at New Stuyvesant High School, exterior/interior, Feb 2002.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000175198
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000179136
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000181582
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260640
TEM analysis results for air samples at New Stuyvesant H.S., 12/31/01 data documented.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260843
TEM results for air samples at exterior and interior of New Stuyvesant High School.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000179341
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis results for air samples from New Stuyvesant H.S., 12/31/01 data documented.
Similar indexed content
TEM analysis results for air samples from New Stuyvesant H.S. exterior/interior, 12/31/01.
Similar indexed content
TEM analysis of air samples from New Stuyvesant High School exterior/interior areas.
Similar indexed content
TEM analysis results for air samples at New Stuyvesant H.S., 12/31/01 data documented.
Similar indexed content
TEM results for air samples collected at exterior and interior of New Stuyvesant High School.
Similar indexed content