NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

IAQ report, 90 Trinity Place, June 7, 2002

Machine-extracted title · confidence 41%

ATC IAQ measurements collected June 7, 2002 at the referenced school.

NYC-WTC_000260537–000260540
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan June 10, 2002 Indoor Air Quality Assessment Page 2 H.S. for Leadership & Public Service (M894) ATC Project No. 15-19125-0290

The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The information presented in this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities.

EVALUAHON CIUTERIA

Curi'ently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in tlie following publications:

Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.

TABLE 1 TARGET GUIDEIJNES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED

B PAKAMETER

Carbon Dioxide TARGET lEVEL

<700 parts per million (ppm) ASHRAE 62 HPI (CO2) above background level Carbon Monoxide 9 ppm ASHRAE 62 (adopted from _______________ USEPA NPAAQS) Respirable 65 micrograms per cubic meter USEPA NPAAQS Particulates (PM2.5) of air (pg/m3) 24-hour average 40 pg/nQ 24-hour average USEPA - Recommendation for children / sensitive individuals Temperature Summer: 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH Relative Humidity 30 - 60 % ASHRAE 55 Total Volatile Organic Compounds 1 ppm AIHA (TVOC) USEPA = United States Environmental Protection Agency NPAAQS == National Primary Ambient-Air Quality Standard AIHA = American Industrial Hygiene Association

CONFIDENTIAL, CITY_21MC100_003464587 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000260538

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000260538Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000260469

ATC provides indoor air quality measurements collected May 23, 2002.

Similar indexed content

NYC-WTC_000260419

ATC provides indoor air quality measurements collected May 20, 2002.

Similar indexed content

NYC-WTC_000260525

ATC IAQ measurements collected June 4, 2002 at the referenced school.

Similar indexed content

Compare copies and versions →