NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

IAQ dashboard report, High School of Economics and Finance, June

Machine-extracted title · confidence 28%

ATC summary of IAQ measurements collected June 4, 2002 at the school.

NYC-WTC_000259487–000259490
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan June 4,2002 Indoor Air Quality Assessment Page 3 H.S. of Economics and Finance (M833) ATC Project No. 15-19125-0291 Real-Time Environmental Measurements

ATC collected one hundred and six (106) sets of real-time environmental measurements consisting of ninety-four (94) inside the school building and twelve (12) outdoors. Field data sheets are found in the Attachment. Readings were collected between morning to evening. The results are described below.

Temperature

Indoor dry bulb temperature measurements ranged from 74.8 °F to 82.5 °F. Eighty (80) of the indoor measurements for temperature were above and fourteen (14) of the measurements were within the range of 73 °F to 79°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the summer season. The outdoor temperature measurements ranged from 71.9 °F to 79.0 °F.

Relative Humidity

The relative humidity indoors ranged from 23.1 percent to 39.6 percent. Nineteen (19) of the indoor measurements for relative humidity bellow the ASHRAE recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity ranged from 22.3 to 28.4 percent.

CarbpnDipxideConcentratipn

Carbon dioxide concentrations indoors ranged from 486 ppm to 1307 ppm. One (1) of the indoor measurements for CO2 was above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentration was 573 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1273 ppm (background level + 700 ppm). The highest concentrations were recorded in room 307 at about 12:29 PM with 20 occupants. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration.

Carbon Mono^eConcentrqtion

Carbon monoxide concentrations indoors ranged from 0 ppm to 1 ppm. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations were 1 ppm.

Respirable Particulates (PM2_5)

Respirable particulate concentrations* indoors ranged between 1 pg/m^ to 26 pg/m^ with an average of 8 pg/m^- None of the indoor measurements for respirable particulates were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter or above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children. The respirable concentrations outdoors ranged between 15 pg/m^ to 66 pg/m^ with an average of 35 pg/m^ •

* The measurements made during this assessment were instantaneous readings, the NPAAQS is

CONFIDENTIAL, CITY_2IMCl00_003462741 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000259489

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000259489Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000396675

IAQ data with TVOCs, CO, and particulates for Trinity Place site, Jun 2002.

Similar indexed content

NYC-WTC_000396620

IAQ measurements collected May 22, 2002 for BOE IAQ maintenance program.

Similar indexed content

NYC-WTC_000396671

IAQ field measurements collected Jun 3, 2002 for IAQ monitoring.

Similar indexed content

Compare copies and versions →