NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: WC BOE VolumeJIrtersl: 1728
Lab Group #: 7366 Filter Type / Filter .Area: MCE 385 mm-
Lab Sample #: 12 Grid Opening Size: 0.01124
Client Sample #: 14 .Area Examined: 0.0562 mm*
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 5 Analysis Date: 4/9/02
Analysis Performed By:
MARK PEYSAKHOV
GO, Structure Structure Type Length ID of Structure N or v EDS
(Nonadb
No F B C M I >=05 y Chrys Amphibole , Nonasb Ambig/ND
No Coord <5p Elements)
Struct = > 0.5u -> 5:1 Aspect Ratio Grid acceptance:
7 = Positive diffraction pattern properties conforming to <50% undissolved filler, overlapped or folded Totals
<10% particulate coverage >50% coverage ate
laboratory ioentification criteria observed
least 20 unfolded or overtappefl grid squares <5% FfB C M >5y
7= EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Chrysotile
AMPHIBOLES ; Amphibole
F = Single Fiber Amosite
3 = Bundle (<3 libers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
Tremolite
M = Matrix
Actinolite Non-Identified
NSD = No Structures Detected
CONFIDENTIAL, CITY_21MC100_003460009