NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 15 pages

Lab analysis report, M833 project, 19125-0291, 32 pages

Machine-extracted title · confidence 41%

Laboratory analysis report for the M833 project; includes lab methods and results.

NYC-WTC_000256996–000257010
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 ■ace Analytical' Minneapolis, MN 55414 Phone 612 6071700 www.pacelab5.com Fax 6126076444 TABLE 4. Method 23 High Resolution Calibration Solutions Concentration (pq/uL) Native CDDs/CDFs CS1 CS2 CS3 CS4 CSS 2,3,7,8-TCDD 0.5 1 5 50 100 2,3,7,8 TCDF 0.5 1 5 50 100 1,2,3,7,8-PeCDD 2.5 5 25 250 500 1,2,3,7,8-PeCDF 2.5 5 25 250 500 2,3,4,7,8-PeCDF 2.5 5 25 250 500 1,2,3,4,7,8-HxCDD 2.5 5 25 250 500 1,2,3,6,7.8-HxCDD 2.5 5 25 250 500 1,2,3.7,8,9-HxCDD 2.5 5 25 250 500 1,Z^;4,7,8-HxCDF 2.5 5 25 250 500 1,2,3,6,7,8-HxCDF 2.5 5 25 250 500 1,2,3,7,8,9-HxCDF 2.5 5 25 250 500 2,3,4,6,7,8-HxCDF 2.5 5 25 250 500 n 1,2,3,4,6,7,8-HpCDD 2.5 5 25 250 500 U 1,2,3,4,6,7,8-HpCDF 2.5 5 25 250 500 1,2,3,4,7,8,9-HpCDF 2.5 5 25 250 500 OCDD 5 10 50 500 1000 OCDF 5 10 50 500 1000 Internal Standards ^^Ci2-2,3,7,8-TCDD 100 100 100 100 100 ’®Ci2-1,2,3,7,8-PeCDD 100 100 100 100 100 ’3C,2-1,2,3,6,7,8-HxCDD 100 100 100 100 100 ’®C,2-1,2,3,4,6,7,8-HpCDD 100 100 100 100 100 ^^Ci2-0CDD 200 200 200 200 200 ’^Ci2-2,3,7,8-TCDF 100 100 100 100 100 ^"C,2-1„3,7,8-PeCDF 100 100 100 100 100 '"C,2-1,2,3,7,8-HxCDF 100 100 100 100 100 ”Ci2-l,2,3,4,6,8-HpCDF 100 100 100 100 100 Surroqate Standards ^’Cl4-2,3,7,8-TCDD 0.5 1 5 50 100 ’^C,2-2,3,4,7,8-PeCDF 2.5 5 25 250 500 ’®Ci2-1.2,3,4,7,8-HxCDD 2.5 5 25 250 500 ’^Ci2-1,2,3,4,7,8-HxCDF 2.5 5 25 250 500 La ^^Ci2-1,2,3,4,7,8,9-HpCDF 2.5 5 25 250 500 Alternate Standard ”C,2-1,2,3,7,8,9-HxCDF 12.5 25 125 1250 2500

Recovery Standards ’’Ci2-1,2,3,4-TCDD 100 100 100 100 100 ’®Ci2-1,2,3,7,8,9-HxCDD 100 100 100 100 100 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc

CONFIDENTIAL, CITY_21MC100_003459343

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000257009

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000257009Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000249395

PACE report header stating lab analysis and project details for sample set 19125-0279.

Similar indexed content

NYC-WTC_000395804

Chain-of-Custody data sheet for Pace Analytical project 6526-0279.

Similar indexed content

NYC-WTC_000396362

Pace Analytical chain-of-custody form accompanying a 31-page lab report package.

Similar indexed content

NYC-WTC_000396324

Chain-of-custody accompanying a Pace Analytical lab report for the project, listing client and sample identifiers.

Similar indexed content

NYC-WTC_000396381

PACE chain-of-custody accompanying a 30-page Pace Analytical report package.

Similar indexed content

Compare copies and versions →