Laboratory analysis report, Pace Labs

Machine-extracted title · confidence 28%

PACE Analytical lab report on Project: [name], with general test details and 23-page document referenced.

NYC-WTC_000256588–000256601
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analyiica/ Semces, Inc. 1700 Elm Street, Suite 200 ’ace Analytical' Minneapolis, MN 55^14 Phone: 612.607 1700 www.pacelabs.cDin Fax: 612.607.6444 TABLE 5. 2,3,7,8-TCDD Equivalency Factors (TEFs) for the Polychlorinated Dibenzo-p-dioxins and Dibenzofurans

Number Compouncl(s) TEF

1 2,3,7,8-TCDD 1.00 2 1,2,3,7,8-PeCDD 0.50 3 1,2,3,6,7,8-HxCDD 0.1 4 1,2,3,7,8,9-HxCDD 0.1 5 1,2,3,4,7,8-HxCDD 0.1 6 1,2,3,4,6,7,8-HpCDD 0.01 7 OCDD 0.001 8 * Total - TCDD 0.0 9 * Total - PeCDD 0.0 10 * Total - HxCDD 0.0 1 1 * Total - HpCDD 0.0

12 2,3,7,8-TCDF 0.10 13 1,2,3,7,8-PeCDF 0.05 14 2,3,4,7,8-PeCDF 0.5 15 1,2,3,6,7,8-HxCDF 0.1 16 1,2,3,7,8,9-HxCDF 0.1 17 1,2,3,4,7,8-HxCDF 0.1 18 2,3,4,6,7,8-HxCDF 0.1 19 1,2,3,4,6,7,8-HpCDF 0.01 20 1,2,3,4,7,8,9-HpCDF 0.01 21 OCDF 0.001 22 * Total - TCDF 0.0 23 * Total - PeCDF 0.0 24 * Total - HxCDF 0.0 25 * Total - HpCDF 0.0

*Excluding the 2,3,7,8-substituted congeners.

Reference: 1389ITEFs

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CONFIDENTIAL, CITY_21MC100_003458774 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000256601

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000256601Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348993

Determination of PCDD/PCDF levels for project: World Trade Center.

Similar indexed content

Compare copies and versions →