December 18, 2001
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Hydrocarbons
Stuyvesant High School
ATC Project No. 15-19125-0246
Dear Mr. Or an;
ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for
hydrocarbon compounds conducted on November 27 and December 7, 2001, at the referenced
school. The New York City Board of Education (BOE) requested this sampling at the
recommendation of H. A. Bader, a consultant to the parents’ association.
On each day, ATC collected three (3) samples for hydrocarbon compounds (HC) at specified
locations. Samples were collected for a imnimum of seven (7) hours using activated coconut
• shell charcoal tubes connected to battery-powered sampling pumps at a flow rate of 0.2 liters per
minute. Pumps were calibrated before and after each sampling period. Two (2) samples were
collected inside the building and one (1) was collected on the roof. One blank tube was also
submitted on each day. The samples were sent to PSC Analytical Services, Inc., an American
Industrial Hygiene Association-accredited laboratory in Reading, PA. Analysis was performed
by capillary gas cnromaiographvTlame ionization detection (NIOSH Methods 1003, 1005, 1022,
1300, 1500, 1501).
Each sample was analyzed for a panel of sixteen (16) specific HC compounds. These compounds
were: pentane, acetone, methylene chloride, hexane, chloroform, methyl chloroform, benzene,
1,2-dichloroethane, trichloroethylene, toluene, perchloroetyhylene (tetrachloroethylene),
chlorobenzene, ethylbenzene, styrene, cumene and xylenes. In addition, two non-identified
peaks, total other A- hydrocarbons and total other B-hydrocarbons, were reported. The A-
hydrocarbons are those, such as gasoline or light alcohols, with boiling points less than that of
benzene (176°F). The B-hydrocarbons are those, such as mineral spirits or petroleum naphtha,
with boiling points greater than that of benzene. Copies of the analytical reports are attached.
The sampling locations were specified by the parents association consultant. They were the 1”
floor lobby, 2'“* floor bridge entrance hallway and the roof.
None of the HCs in the panel were present above the limits of detection an either day.