A total of five (5) settled dust bulk samples were collected from the aforementioned areas where
there was sufficient amount of settled dust for bulk sampling and were analyzed utilizing
Polarized Light Microscopy (PLM).
Analytical results indicated that the settled dust bulk sample collected from the South end of 2"''
floor hallway contain 2% fiberglass fibers. All other collected bulk samples contain less than 1%
fiberglass fibers.
ATC recommends the following;
• A custodial cleanup should be performed at the South end of 2"** floor hallway
• Additional bulk samples should be collected after the custodial cleanup is completed on
the 2"“^ floor hallway. If collection of bulk samples is not possible, settled dust samples
should be collected from the 2"'' floor only utilizing the 3M Scotch Magic Tape - An Aid
to the Microscopist for Dust Examination method by Gary Nichols. All collected settled
dust samples should then analyzed utilizing Polarized Light Microscopy (PLM). This
method will produce qualitative results only.
The settled dust bulk sampling performed was limited to testing for fiberglass in locations
indicated by ENVIRON Corp, and as outlined in the school’s BOE approved sampling protocol.
Attached please find the following:
• Settled dust bulk sample chain of custody form and laboratory results
• Laboratory and personnel certificates
If you have any questions or require additional information regarding this limited settled dust
bulk sampling, please do not hesitate to contact me at (212) 353-8280 extension #261.
Sincerely,
.Yimfeas Ci. Andreou
Senior Project Manager
Cc; Mr. T. Fusillo (ENVIRON Corp.)
Ms. C. Procter (UFT)
Mr. C. D’Andrea (NYC-DOH)
CITY_21MC100_000490419