NYC 9/11 Public Portal Document
Scope of Work
ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC-
BOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples were
collected from areas recommended by the Parents Association consultant representative
Mr. Tom Fusillo of ENVIRON Corp, and approved by NYC- BOE and as specified in the
sampling protocol for the school. These areas are the following:
Lobby
© Multipurpose room near kitchen
© Two randomly selected classrooms
The purpose of the dust wipe sampling is to determine if dust in the school contains lead.
ATC will be repeating this sampling preferably every Monday as per the recommendation
of ENVIRON Corp, and after the approval of NYC-BOE. This is the 19* consecutive
time dust samples were collected from P.S. 150M to be analyzed for lead content after the
sampling protocol is approved.
ATC’s representative Mr. Mark Nakhumovich visited P.S. 150M located at 334
Greenwich Street, New York, NY on May 27, 2002. Dust wipes to be analyzed for lead
content were collected from the aforementioned areas indicated by ENVIRON and as
specified by the New York City Board of Education Environmental Health & Safety Unit
and in accordance with HUD protocols.
LEAD-IN-DUST SAMPLING
Lead-in-dust threshold levels
The New York City Health Code, part 173.14 and the Federal Departments of Housing and
Urban Development (HUD) and Environmental Protection Agency (EPA) have established
acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred
(commonly referred to as “final clearance” levels). As stated in the Code, final clearance
after abatement has taken place is achieved when dust wipe samples indicate lead levels
below those listed below:
For Windowsills: 250 pg/ft-
For Floors: 40 pg/ft"
Although the lead-in-dust samples collected at P.S. 150M were not collected in response to
lead abatement, the same thresholds are used since no other regulations or standards are
applicable to this project.
Sampling Methodology
ATC provided all laboratory analytical services in support of this limited inspection. ATC
is certified by the New York State Department of Health’s Environmental Laboratory
Accreditation Program to perform lead and related analyses of environmental samples
P.S. I50M
May 28, 2002
CONFIDENTIAL, CITY_21MC100_001902897
SUBJECT TO PROTECTIVE ORDER NO. 2. SEPT. 2008
NYC-WTC_000253537