NYC-WTC_000388581
Draft GC/MS results for ambient air samples near WTC site, listing sample IDs and locations.
4 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗Draft GC/MS results with multiple sample IDs and locations including Plaza and Tower.
NYC-WTC_000251896–000251897OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
■ ’’J
DRAFT GC/MS Results for 10/04/01 DRAFT Tentatively Identified
File name jNYC223 NYC224 NYC225 Sample Location iMethod Blank Tedlar Bag Blank Ambient blank Sample Number I Sample Height I Breathing Volume I Iwo ml 100mL
W [None None I None G to G M O H File name NYC226 NYC227 NYC229 Sample Location Amec Vent #1 Amec Vent #2 Plume 51 H O Sample Number 1040 1040 1140 Sample Height Ground Ground Ground 3 3 Volume 10 mL 50 ml 50 mL O Methyl-1-Propene 5100 ppb C4 alkene 1200 ppb__________ 2-Methyl-1-Propene 45C H M alkane 1900 ppb______________ alkane 410 ppb______________ Alkane 240 ppb_______ O O Pentane 3400 ppb ___________ Pentane 900 ppb_____________ Pentane 250 ppb_____ H o Furan 2300 ppb_______________ Acetonitrile 570 ppb__________ Furan 250 ppb_______ 3 3 Acetonitrile 2200 ppb___________ Methyl Ester Acetic Add 570 ppb 2-Methy1-Furan 420 ppb O Methyl Ester-Acetic Acid 2900 ppb 2-Methyt-Pentane 210 ppb C3-Alkyl Benzene 480 pp o M C5 Cydoalkene 1100 ppb_______ Cydopentene 280 ppb _______ 3 1-Hexene 1200 ppb____________ 2-melhyl-1-PentenB 300 ppb a H M 2,3-Dimethyl-2-Butene 1200 ppb C6 Cycloalkane/alkene 330 ppb 2 > 2-Methyl-Furan 6900 ppb_______ 2-melhyt-Furan 1500 ppb______ 2 2,5-Dimethyl-Furan 1200 ppb C6 cycloalkene 220 ppb_______ O Cydopentanone 1400 ppb______ l-Butanol 210 ppb____________ unknown 1100 ppb____________ 2.S-dimelhyl-Furan 280 ppb to C9 alkene 1000 ppb___________ Pyridine unknown 290 ppb C3 alkyl benzene 3100 ppb______ Cydopentanone 250 ppb______ w .alpha.-Methylstyrene 1300 ppb C3 alkyl benzene 850 ppb M 3 C3 alkyl benzene 220 ppb_____ H ■alpha.-Methylstyrene 370 ppb 2-ethyl-1-Hexanol 220 ppb to Benzonitrile 200 ppb o o co File name NYC231 NYC232 NYC233 O Sample Location Sample Number Location 2 1004 Liberty + West #1 1212 Austin Tobin Plaza #3 1230 NO QC EVALUATION HAS BEEK PERFORMED, I Sample Height Volume Breathing 250mL Breathing 100 mL Breathing 100mL DATA VALIDITY IS UNSUBSTANTIATED AND THE DATA SHOULD BE USED [None In^ iNone WITH DBCRniOH > O O ;‘-G' - .Gt I o ' •'•U o co 1 co co co co ho co
NYC-WTC_000251897
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000388581
Draft GC/MS results for ambient air samples near WTC site, listing sample IDs and locations.
4 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251878
Draft GC/MS results showing vent samples from S.Tower North West and adjacent areas.
4 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251853
Draft GC/MS results with sample numbers and solvent concentrations for Oct 25, 2001.
4 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251874
Draft GC/MS results with samples from North Tower areas and surrounding locations.
3 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251857
Draft GC/MS results for Oct 24, 2001, showing sample IDs and target compounds.
4 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178310
Preliminary draft gas chromatography-mass spectrometry data for volatile organic compounds from World Trade Center site samples dated October 27, 2001.
2 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251888
Draft GC/MS results with multiple analytes and sample volumes for North Tower area.
3 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251902
Draft GC/MS results for Liberty & Greenwich sites with several sample entries.
2 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251898
Draft GC/MS results listing samples from Middle North Tower areas and surrounding sites.
3 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000368959
Draft GC/MS results for samples from 25 Pace U. Spruce + Park site, listing sample numbers and instrument readings.
1 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307556
Draft GC/MS results for multiple NYC samples with target compounds and ambient levels.
3 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000368913
Draft GCMSR with ambient samples; NYC Response
3 shared non-person entities · 1 shared topics · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000252036
Draft GC/MS results showing ambient sampling at North Park Pier 25 and related sites.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251860
Draft GC/MS results with multiple NYC locations, sample volumes and analyte levels.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000252028
Draft GC/MS results including sample numbers for NYC510-515 and North Park Pier 25.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000252026
Draft GC/MS results showing ambient sampling at North Park Pier 25 and associated locations.
Similarity score 0.972 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251995
Draft GC/MS results for NYC227- NYC231; North/South Tower locations indicated.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000252023
Draft GC/MS results including file names and sample volumes for multiple NYC locations.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000388581
Draft GC/MS results for ambient air samples near WTC site, listing sample IDs and locations.
Similar indexed content
Draft GC/MS results showing vent samples from S.Tower North West and adjacent areas.
Similar indexed content
Draft GC/MS results for samples from 25 Pace U. Spruce + Park site, listing sample numbers and instrument readings.
Similar indexed content
NYC-WTC_000251853
Draft GC/MS results with sample numbers and solvent concentrations for Oct 25, 2001.
Similar indexed content
Draft GC/MS results for multiple NYC samples with target compounds and ambient levels.
Similar indexed content