Z Z
KAM CONSULTANTS
o 3$*4O36HiStmt o
co
Itano.
g Long Island City REPORT OF AIR MONITORING
I
O New York, 11106 (PHASE CONTRAST MICROSCOPY ANALYSIS OF AIR FILTERS) “0
o
o Tel: (718)729-1997 c
CT
o Fax:(718)729-1876 CLIENT: DCAS DATE: 09/27/01
ro o'
cn PROJECT: ADDRESS: 125 Worth Street, Manhattan "0
o> 10th. Sth, 6th, 4th, 2nd,& 1st Floor o
o> CD
R W
CLIENT FLOW FLOW SAMPLE FIBERS FIBERS
SAMPLE LOCATION
E o TIME TIME
BEF. AFTER VOLUME PER PER REMARKS LAB ID#
0
o
S R IN OUT o
ID# (Ipm) (Ipm) (liters) FIELD CC c
P K
3
24 1st Floor Lobbies - East Entrance Centre Street 12:35 14:35 10 10 1200 <0.055 <0.01 Air Quality (Immed. TAT) A010928H-24 CD
3
25 Field Blank <0.055 A010928H-25
26 Field Blank <0.055 A010928H-26
27 Field Blank <0.055 A010928H-27
TYPE OF RESPIRATORS: 1 = HALF FACE, 2 = PAPR, 3 = TYPE C, 4 = OTHER (SPECIFY):
TYPE OF WORK: 1= BLDG DECON, 2 = PLASTICIZING, 3 = GROSS REMOVAL, 4 = GLOVEBAG, 5 = CLEANING,
6 = ENCAPSULATION, 7 = BAGOUT, 8 = OTHER (SPECIFY):
o SAMPLING TECHNICIAN: M. Golembo. M. Tchatchueng, Z.B. Nowak DATE RECEIVED: 09/28/01
ROTAMETER: KAM- 04 DATE OF ANALYSIS: 09/28/01
DATE OF REPORT: 10/01/01
Analyst: Lab Manager:
S !pak Bajracharya David Chen
o
The samples listed above are analyzed by Phase Contrast Microscopy (PCM) as per NIOSH 7400 Method -Issue 3. The detection limit of this method is 7 fibers per square mm per filter area.
O
O KAM CONSULTANTS shall not be liable for information arising from samples that are not in its QA and QC program.
I The results relate only to the items calibrated or tested. The certificate of report shall not be reproduced without approval of the laboratory.
o
The report must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government.
co NYS-DOH ELAP #11273 A IHA # 100269
to 2
Ui
Cn
to
OCR can misread numbers and units. Confirm readings against the page image before using them.