NYC 9/11 Public Portal Document
hand-picked from the centrifugate and identified by both polarized light microscopy (PLM) and
transmission electron microscopy (TEM), and then their dimensions were measured. On
mounted point counting filters, amphibole fibers can be classified only on the basis of
morphology, birefringence, and optical sign. Accordingly, on the point counting filters,
discrimination between amosite and actinolite/richterite asbestos is not possible. Numerically,
these amphibole asbestos fibers were infrequent, and did not contribute to the point counting
data. The amount of amphibole asbestos on the point counting filters could be quantified,
however, by measuring the dimensions of the fibers. The weight percent of amphibole asbestos
was calculated from the dimensional measurements made on both the fibers hand-picked from
the sediment and the amphibole asbestos fibers observed during the point counting. The weight
percent of chrysotile was calculated from the weight of hand-picked fibers and the results of the
point counting.
5.3.3 Results
Table 22 presents the summary results of the analyses of samples of exterior dust and
debris.
The material collected from the roof of the automobile contained 0.67% chrysotile by
weight, and the material collected from the roof outside the Sth Floor loft at 45 Warren Street
contained 1.05% chiysotile by weight. Fibers hand-picked from the centrifugates showed that
actinolite asbestos and richterite asbestos were present in both of these samples, amosite was
present in the sample collected from the roof outside the Sth Floor loft at 45 Warren Street, but
no amosite was detected in the sample collected from the roof of the automobile on Church
Street. During point counting of filters to determine the presence of chrysotile in these two
samples, amphibole asbestos fibers were observed. Because most of the amphibole asbestos
hand-picked from these two samples was actinolite/richterite asbestos, it is reasonable to
conclude that the fibers on the corresponding point counting filters are also primarily
actinolite/richterite asbestos. Based on this assumption, the concentration of
actinolite/richterite asbestos in the sample collected from the roof of the automobile on Church
37