5.0 ASBESTOS MEASUREMENTS
5.1 Asbestos in Passive Air Samples
5.1.1 Sample Collection
Air samples were collected using 25-mm-diameter 3-piece plastic cassettes with short
cowls. Each cassette contained a 25-mm-diameter, 0.45-p.m porosity, mixed esters of cellulose
(MCE) filter, with a 5.0-um MCE back-up filter and a cellulose support pad. Each sampler
operated at a flow rate of approximately 9 liters/minute and was calibrated at the start and finish
of sampling. All air sampling was conducted under passive conditions, and no air conditioning
or ventilation systems were operating at the time of sampling. Considerable amounts of settled
dust and debris were present on all horizontal surfaces in each of the apartments where the
indoor samples were collected. Disturbance of this surface dust was minimized, personnel were
near the air samplers only to monitor their operation, and dust and debris samples were
collected with a minimum of disturbance.
At 45 Wanen Street, three air samplers were positioned in the 2nd Floor apartment and
three in the Sth Floor apartment. An exterior sample was also collected on the roof outside the
5th Floor loft. Each of these samplers operated over a period of time sufficient to collect the
particulate material from approximately 1200 liters of air. An open field blank and a closed
field blank were included with this set of air samples.
At 250 South End Avenue, five samples were collected in Apartment lOD, and one
exterior sample was collected by positioning the cassette outside a sliding window. An open
field blank and a closed field blank were included with this set of air samples. The intent was
to collect particulate material from approximately 1200 liters of air, but the sample collection
had to be terminated prematurely because the filters were becoming overloaded.
5.1.2 Analysis f
The sample filters from 45 Warren Street were prepared and analyzed by transmission,
electron microscopy (TEM) using the direct-transfer method ISO10312. An initial attempt to
prepare TEM specimens by ISO 10312 from the air sample filters from 250 South End Avenue