NYC-WTC_000417655
Foreword and protocol for 30 residential building investigations around WTC indoor environments.
17 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Final draft chain-of-custody for ambient dust evaluations near the World Trade Center, Nov 2001.
NYC-WTC_000250891–000250931OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
****pjj\iAL DRAFT (Version 11), November 8, 2001**** ♦Screening Guidelines = are levels for the general public that require further evaluation. Levels measured above a screening value does not indicate that adverse health effect will result. ** As sampled in “Ambient and Indoor Sampling for Public Health Evaluations of Residential Areas Near WTC.” W
pH Guidelines
The pH of a substance represents the hydrogen ion concentration of the substance. The range of pH values is generally from 0 to 14 with 7 being considered a neutral pH. Substances with a pH of less than 7 are considered to be acidic and will yield hydrogen ions when they are in solution. Acids will change litmus paper red. A base is a substance with a pH greater than 7 and will yield hydroxyl ions in solution. Bases will react with acids to form salts and water. In the body, a normal balance between acids and bases is maintained that keeps the extracellular fluids in the body with a pH between 7.35 and 7.45. A pH out of this range indicates a state of acidosis or alkalosis. Regulation of the pH in the body depends on the function of the lungs and the kidneys.
Guidelines for the interpretation of the pH values of the dust samples being proposed are included in this plan to assist in defining what role if any that the pH may be in the irritant properties of the dust. An irritant effect is one where the tissue has been stimulated and responds with a reversible W inflammatory response. Common symptoms from exposure to an irritant are cough, burning of eyes, nose, & throat, tearing, dyspnea, and wheezing.
There are very few standards for the regulation of the pH of a substance. The national Secondary Drinking water standards set the pH range at 6.5 - 8.5. EPA has established guidelines for the testing of the acute dermal irritation and the acute eye irritation properties of substances. Those guidelines state that it is not necessary to test substances with a pH of less than 2.0 or greater than 11.5 as they are known to be corrosive. A corrosive is a highly reactive substance that causes irreversible damage to living tissue after less than 4 hours of exposure. Using this information as a basis, the following guide is proposed:
IB Acid/base Properties 0-2.0 Strongly acidic Corrosive >2.0 - 6.5 Weakly acidic Irritant >6.5 -8.5 Neutral >8.5 - 11.5 Weakly basic Irritant >11.5 Strongly basic Corrosive
Page 40 of 41
NYC-WTC_000250930
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000417655
Foreword and protocol for 30 residential building investigations around WTC indoor environments.
17 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321610
Foreword describing residential dust and indoor air sampling protocol near the WTC, Feb 2002.
17 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164784
Transmission of revised asbestos sampling results for residential samples collected November-December 2001.
18 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433409
Ambient and related sampling plan for post-9/11 WTC-area residences.
17 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000417471
Indoor and dust sampling protocol for residential buildings near WTC, Feb 2002.
17 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435156
Ambient and indoor sampling protocol for WTC-related residential buildings, foreword Feb 2002.
17 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443008
Foreword describing indoor and dust sampling protocol for WTC residential study, Feb 2002.
17 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434214
Overview of residential building dust/air sampling protocol post-9/11; alignment with DOH/EPA/OSH.
17 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434468
Foreword/protocol for ambient/dust evaluation in 30 residential buildings post-WTC.
17 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164732
Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.
18 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153220
Draft protocol outlining objectives and locations for assessing airborne and settled dust exposures in residential areas.
15 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139712
Series of emails forwarding a draft memo between DEP staff members for review and finalization.
18 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000250481
Interpreting sampling results and when health review is warranted.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237907
Draft sampling protocol developed to assess airborne and settled dust exposures in residential areas near the World Trade Center following the collapse.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306628
Draft ambient sampling protocol for residential exposure near WTC.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178091
Sampling protocol developed to assess residential exposure to airborne and settled dust near the World Trade Center.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241933
Draft ambient sampling protocol for WTC-related fiber and dust exposure assessments.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153200
Public health guidance on reducing exposure to smoke and dust from WTC collapse.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000164784
Transmission of revised asbestos sampling results for residential samples collected November-December 2001.
Similar indexed content
NYC-WTC_000433409
Ambient and related sampling plan for post-9/11 WTC-area residences.
Similar indexed content
NYC-WTC_000417471
Indoor and dust sampling protocol for residential buildings near WTC, Feb 2002.
Similar indexed content
NYC-WTC_000435156
Ambient and indoor sampling protocol for WTC-related residential buildings, foreword Feb 2002.
Similar indexed content
NYC-WTC_000417655
Foreword and protocol for 30 residential building investigations around WTC indoor environments.