Lab report: DOH evaluation near WTC, Oct 12, 2001

Machine-extracted title · confidence 45%

DOH evaluation document for health assessment in WTC-affected area.

NYC-WTC_000250593–000250602
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z Z o o co g o I “0 o c o CT o IV. Sampling Parameters: ro o' cn Parameter Sample Type Indoor/Outdoor Rationale for Selection "0 o I/O knov.Ti use in building construction, evidence of o cn Asbestos breathing ht., CD o> time-weighted presence in early air sampling and in settled dust, 03

air known inhalation carcinogen O o o c Total Suspended breathing ht.. o Characterize amount of airborne dust that is 3 inhalable (fi 100 pm aerodynamic diameter) CD particulates Continuous, real­ 3 time, air

PMIO and PM2,5 breathing ht.. o Characterize the amount of airborne dust that is Continuous, real­ respirable time, air

Inhalable (< 100pm)' breathing ht., I/O To determine relative amounts of each fraction present thoracic (<10pm)* time-weighted, and to have each fraction analyzed for silica, gypsum, respirable (<4pm)‘ air asbestos, mica, and calcite to qualitatively determine potential hazards.

Respirable breathing ht., I/O Known component of concrete, evidence of crystalline silica time-weighted, presence in some settled dust samples, known air inhalation carcinogen.

pH" dust I/O Concrete has a high pH, if dust has a high pH, it may be contributing to reported symptoms of ENT irritation

Asbestos" dust I/O Determine if asbestos is present in dust

* results will be used to better understand the potential for ENT and respiratory irritation, and possibly for determining the possibility of acute/chronic health problems. Results will assist in providing information/recommendations to the public (e.g., what is contributing to irritation, how to reduce exposures)

" to assist in characterizing dust that can become airborne (re-intrainment of settled dust that may be the source of continuing air contamination), and to make' recommendations for outdoor dust remediation

n H;

cS n o o ■ Page 4 of 12 I o 1—1

co kO

<7*

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250596Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000153247 · Box DEP Box 26

Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.

Similar indexed content

Compare copies and versions →