NYC-WTC_000317925
Draft chain-of-custody outlining ambient and residential dust sampling near WTC with exposure rationale.
13 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗Public-facing notes on reducing exposure to smoke and dust from WTC fires.
NYC-WTC_000250587–000250592OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
DRAFTOctober 18,2001 2:45 PM worker irritation. ( Do we want to consider using a lower number, say 1/5 or 1/10 of this value to address sensitive populations and time weighting issues?) For the two smaller particulate fractions, thoracic and respirable, the results will be compared to 24 hour ambient air standards for PM|(, and PM 2 5 respectively, as screening levels, hi addition, the samples collected outdoors in breathing zone air outside buildings that were or are affected by dust or smoke from the WTC can also be compared to results from sampler units placed in similar locations, not in or near buildings affected by the WTC, to evaluate whether particulate concentrations in the affected areas significantly differ from those that would routinely occur on a city street. Monitors placed at street level can be significantly influenced by short-term local sources of particles such as car, truck and bus traffic.
For the collection of indoor samples for the three size ranges of particulates, the sampling plan recommends locating the sampler in such a way as to evaluate “worst case conditions”. Often this may be in the entry way where particles may be blown in or tracked in. In other words, the monitors will placed where particles are most likely to be found, not necessarily where an occupant would spend the most time. While some indoor particles come from outside, many particles in the size ranges that will be measured are generated and stirred up by activities inside the home. There are many human and household factors that can dramatically influence air concentrations of particles in the home. The frequency and intensity of activities that introduce particles into the air (e.g. smoking, cooking, candle and incense burning, and cleaning) coupled with a home’s ventilation status (which could remove or introduce particles) will all influence airborne particle concentrations in a home at a specific time. Because individual home characteristics vary so widely, and indoor and outdoor sources of particles vary, there is no reliable characterization of what a “background” or average residential air concentration of particles would be. The indoor samples will be compared to both the screening levels and to the sampling results from the control dwellings in NYC which were not affected by dust and smoke from the WTC. If the sampling determines that airborne particles exceed levels measured in the control homes and the screening values, further efforts will be made to identify sources and appropriate cleaning techniques. If warranted additional air sampling, such as personal monitoring may be recommended to better characterize actual exposures rather than “worst- case” conditions.
Recommendations:
The Environmental Assessment Workgroup is providing the following recommendations to help people reduce their exposure to particulate matter and make well-informed decisions about their health.
1. People with respiratory or heart disease, the elderly and young children, should avoid prolonged exposure to dust and suspended particles.
When dust and smoke are present outdoors, limit time outdoors.
CITY_21MC100_013489422 NYC-WTC_000250590
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000317925
Draft chain-of-custody outlining ambient and residential dust sampling near WTC with exposure rationale.
13 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241933
Draft ambient sampling protocol for WTC-related fiber and dust exposure assessments.
12 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338190
Draft sampling protocol for ambient asbestos and dust exposure near World Trade Center residential areas.
13 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178091
Sampling protocol developed to assess residential exposure to airborne and settled dust near the World Trade Center.
12 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241970
Draft protocol addressing settled surface dust and airborne materials post-WTC collapse.
8 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250547
Ambient and residential evaluations near WTC, draft protocol version 9.
12 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153208
Public health guidance on reducing exposure to smoke and dust particulates following the WTC collapse.
11 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153200
Public health guidance on reducing exposure to smoke and dust from WTC collapse.
12 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000142610
Informational text defining airborne particulate matter and its sources in the context of September 11 environmental monitoring.
5 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000142607
Informational text defining airborne particulate matter and its sources in the context of September 11 environmental monitoring.
5 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000142687
Fact sheet answering public questions about prolonged fires at the World Trade Center site and potential health impacts.
9 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152801
Correspondence forwarding a revised indoor air sampling plan focusing on residential areas and concentric zones.
8 shared non-person entities · 1 shared topics · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000317925
Draft chain-of-custody outlining ambient and residential dust sampling near WTC with exposure rationale.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153208
Public health guidance on reducing exposure to smoke and dust particulates following the WTC collapse.
Similarity score 0.965 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338190
Draft sampling protocol for ambient asbestos and dust exposure near World Trade Center residential areas.
Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338190
Draft sampling protocol for ambient asbestos and dust exposure near World Trade Center residential areas.
Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153208
Public health guidance on reducing exposure to smoke and dust particulates following the WTC collapse.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153200
Public health guidance on reducing exposure to smoke and dust from WTC collapse.
Similarity score 0.956 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Public health guidance on reducing exposure to smoke and dust particulates following the WTC collapse.
Similar indexed content
NYC-WTC_000153200
Public health guidance on reducing exposure to smoke and dust from WTC collapse.
Similar indexed content
NYC-WTC_000142610
Informational text defining airborne particulate matter and its sources in the context of September 11 environmental monitoring.
Similar indexed content
NYC-WTC_000142607
Informational text defining airborne particulate matter and its sources in the context of September 11 environmental monitoring.
Similar indexed content
NYC-WTC_000317925
Draft chain-of-custody outlining ambient and residential dust sampling near WTC with exposure rationale.
Similar indexed content