NYC 9/11 Public Portal Document
kwte residential plan octlS.wpd Page 2 i
****])RAFT*^-^*
environmental health issues. Burning throats have been reported to be a common problem in the
recently re-occupied residential areas. Residents in south Battery Park City, whose windows
were open at the time of the WTC collapse, have settled dust in their homes. Some have
disposed^f fiimiuure, stereo equipment, etc., because they were covered with "ash and dust."
Homes ii^tKe'^ Tri Deca zone (Chambers Street to Murray Street, west of Broadway) are not yet
occupied, but were reported to have roofs covered with hand-sized chimks of insulation-Uke i
material that contain small pieces of mica-like material. In addition, the mica-like material has
clogged roof drains and resulted in standing pools of water on residential roof tops.
I
II. Sampling Objective:
Tlie overall objective of this sampling is to provide results upon which public health agencies can
fiirther determine the potential for environmental e.xposures to WTC collapse-related materials
and possible health impheat ions of the exposures. Sampling will characterize ambient and indoor
airborne and potentially airborne particles (surface dust) that remain in residential areas and
Qnmmgrcial areas-'of lower Manhattan from the collapse of the World Trade Center. Specifically,
the objective is:
Characterize the make-up and size distribution of settled dust and airborne breatliing
zone dust in residential areas-both indoors and outside-near the WTC. This information
will be used to further determine if materials are present in air at levels of public health
concern; and if materials are present in settled surface dust that can be re-entrained and c il g.
SampleJocations will be selected in a concentric circle pattern, starting close to the WTC and tR-vv
ending ill neighboring boroughs. Section V, Residence Selection/Sampling rationale, of this o^Vc.
protocol describes this approach. j
in. Data and Quality Assurance:
I
Co-located samples will be collected in 10% of the air samples. While not a true duplicate,
evaluation of the results will provide some information on the quality of the sampling teclmique.
Generally, analysis of dupheate samples should be within +/- 20% of each other.
At least two field blanks (or 10% of samples submitted, whichever is greater) per sample location
will be submitted with the air samples. Blank cassettes should be opened at the same time as the
sample cassettes are opened (just prior to sampling). Blank cassettes and their covers should be
stored in a clean area (e.g., closed bag or box) with the covers fi-om the sampling cassettes during
the sampling period.
Each air sampling pump will be calibrated with a representative sampling device in-line before and
after sample collection. Sample flow rates will be documented in the sampling log. The average
2
j
CITY_2IMCl00_013489377
NYC-WTC_000250548
OCR can misread numbers and units. Confirm readings against the page image before using them.