Residential PM results analysis, chain-of-custody, 2002

Machine-extracted title · confidence 46%

Draft report on PM results with sample weights and concentration calculations.

NYC-WTC_000250387–000250434
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mar-19-02 10:3flan From- T-326 P.031/055 F-856

sampling event 15, results were available for two blanks and sample from the common area, outdoor, and two residences. The weight gain of each blank was divided by the sample volume drawn through the sample filter in each of those four sampling locations. The resulting blank concentrations were compared to the associated sample concentration. The “By Building” sheet in the “Blanks vs Samples_Feb28.xls” file shows all of the results for each sampling event where results are available.

As a result of this comparison method, the number of results for blanks increases when they are expressed as concentration. Only one or two results of blanks by weight gain are available for each sampling event. Where as up to four concentration results could be calculated using available sample air volumes. However this method would only affect the number of blank results (by concentration) and would not significantly affect the range of the blank results (by concentration).

Figures 8 through 11 show the distribution of the blanks by concentration and the concentrations measured in each of the sampling areas for each particle size. The vertical axis shows the concentration [mg/m3] measured in each sampling area and calculated for the associated blanks. There are three horizontal lines across the each graph illustrating the screening value, detection limit (DL) and reliable detection limit (RL) for each particle size. Figures 8 and 9 show all of the measured sample filter concentrations along with all but the high PMIOO blank and the low PMIO blank. Figures 10 and 11 show all of the measured and blank data available. There is no figure 12.

Figures 13 through 24 show the same information in a different format. Each sampling location for each particle size fraction is show with it’s associated blanks. The PMIOO graphs (Fig 13 -15) include ^1 of the available data and can be found in “PMIOO Graphs.xls”. The PMIO graphs (Fig 16-18) do not include the entire data set. The blank with a weight gain of -90 mg is not included because the resulting concentration is approximately -60 mg/m3. This value was not included in order to see the remaining distribution. The PMIO graphs can be found in PMIO Graphs.xls”. The PM4 graphs (Fig 19 - 21) contain all of the available data and can be found in “PM4 Graphs.xls”. The PM2.5 graphs (Fig 22 - 24) contain all of the available data and can be found in PM25 Graphs.xls”.

Figures 13 through 24 show the measured concentration of a particle size in a sampling location along with the calculated concentration of the associated blanks. The goal was for two blanks to be analyzed for each sampling event (building), these were arbitrarily labeled ‘blank A’ and ‘blank B’. For the PMIOO and PMIO size fractions results for both blanks A and B tended to be available for the majority of the sampling events. For PM4, results for both blanks A and B were available up to sampling event number 21, from sampling event 21 through 34 only one blank result was available. PM2.5 sampling equipment was not available until sampling event number 21. For PM2.5 only the results of one blank are available for each sampling event. Sometimes this one blank was labeled ‘A’ and for others ‘B’.

24

NYC-WTC_000250410

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250410Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →