Lab report, ATC sample, PCDD/PCDF, 2001

Machine-extracted title · confidence 38%

Determination of PCDD/PCDF levels for ATC at NYC site, report for client.

NYC-WTC_000250102–000250122
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Serrices, Inc. 1700 Elm Street, Suite 200 weAnalyticar Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE: March 5, 2002

PAGE: 3 REPORT NO: 02-1054208

PCDD/PCDF Analyses (Cent.)

The mass spectrometer was operated in the electron impact ionization mode at a mass resolution of 10,000-11,000 (M/AM, 10 percent valley definition). This resolution is sufficient to resolve most interferences, such as PCBs, thus providing the highest level of confidence that the detected levels of PCDD/PCDF were not false positives resulting from interferences. Typical operating parameters for the HRGC/HRMS analyses are summarized in Table 2.

The data were acquired by selected-ion-recording (SIR) using groups of ion masses similar to those described in USEPA Method 8290. The five groups corresponded to the tetrachlorinated through octachlorinated congener classes. Each group contained two ion masses for the PCDDs, two ion masses for the PCDFs, the corresponding ion masses from the two isotopically labeled internal standards, and the ion mass characteristic of the polychlorinated diphenylether (PCDE) which, if present, could cause false responses in the dibenzofuran channels.

Each group of ion masses also contained a lock mass which was used by the data system to automatically correct the mass focus of the instrument. The data system determined the centroid of the lock mass during each data acquisition cycle and corrected the mass focus of the analyte and internal standard ion masses to assure that the centers of the mass peaks were being monitored.

The criteria used to judge positive responses for a PCDD/PCDF isomer included:

* Simultaneous response at both ion masses of the PCDD or PCDF Signal-to-noise ratio equal to or greater than 2.5:1.0 for both ion masses * Chlorine isotope ratio within 15% of the theoretical value * Chromatographic retention time within -I-/- 2 seconds of the expected retention time * Chromatographic retention times within elution windows determined from analyses of standard mixtures * Absence of simultaneous response in the PCDF and PCDPE ion traces

A list of the exact ion masses monitored for the determination of PCDD/PCDF isomers and the PCDE interferences is presented in Table 3. Also included are the theoretical chlorine isotope ratios for the ten congener classes.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

/Ox CONFIDENTIAL, CITY_21MC100_005760073 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000250105

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250105Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000375724

Laboratory results for project 19125-0289 with PGDD/PCDF determinations, 21 pages.

Similar indexed content

NYC-WTC_000375748

Laboratory analysis report for ATC project, TEM/analysis, 21 pages.

Similar indexed content

Compare copies and versions →