NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 29 pages

Lab report, PCDD/PCDF analyses, ATC, 2002

Machine-extracted title · confidence 54%

PACE Analytical report on PCDD/PCDF analyses submitted by ATC, Jan 2002.

NYC-WTC_000249257–000249285
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 weAnalyticar Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

' PROJECT: PCDD/PCDF ANALYSES DATE: January 9, 2002

PAGE: 2 REPORT NO: 01-1052540

PCDD/PCDF Analyte Enrichment

The extraction procedure often removes a variety of compounds, in addition to the PCDDs and PCDFs, from the sample matrix. Some of these compounds can directly interfere with the analyses while others can overload the capillary column causing degradation in chromatographic resolution ■ or sensitivity. The analyte enrichment steps described below are used to remove interferences from the extracts. R Each extract was diluted to 100 mL with hexane, transferred to a separatory funnel, and washed with IN sodium hydroxide, concentrated sulfuric acid, and aqueous sodium chloride (5% w/v) as , 1 needed. The hexane extract was quantitatively transferred to a liquid chromatography column containing alternating layers of silica gel, 40% concentrated sulfuric acid on silica gel, and 33% 1 N sodium hydroxide on silica gel. The column was eluted with 90 mL of hexane and the entire i eluate was collected and concentrated, under ambient conditions, to a volume of 1 mL.

Each extract was then fractionated on a liquid chromatography column containing 4 g of activated alumina. The column was eluted with 20 mL of hexane followed by 1 5 mL of 60% methylene chloride/hexane. The 60% methylene chloride/hexane fraction was concentrated to 1 mL under a - J stream of dry nitrogen and applied to the top of a chromatography column containing 1 g of 5% : J AX-21 activated carbon in silica gel. The column was eluted with two 2-mL portions of hexane, 2 ’ mL of cyclohexane/methylene chloride (50:50 v/v) and cyclohexane/methanol/toluene (75:20:5 ! 'I v/v) in the forward direction, and then with toluene in the reverse direction. The toluene fraction was collected, concentrated, spiked with recovery standards (1,2,3,4-TCDD-'^Ci2 and 1,2,3,7,8,9- HxCDD-^^Ci2) and taken to a final volume of 20 uL.

PCDD/PCDF Analyses

La Each sample extract was analyzed for the presence of PCDDs and PCDFs using combined capillary column gas chromatography/high resolution mass spectrometry (HRGC/HRMS). The instrumentation consisted of a Hewlett Packard Model 6890 gas chromatograph interfaced to a Lj Micromass Ultima high-resolution mass spectrometer. The capillary column was interfaced directly into the ion source of the mass spectrometer, thus providing the highest possible sensitivity while minimizing degradation of the chromatographic resolution.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services. Inc.

CONFIDENTIAL, CITY_21MC100_003474142 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000249258

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000249258Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

PCDD/PCDF lab analysis results, Jan 2002

NYC-WTC_000226877

Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.

Similar indexed content

NYC-WTC_000272110

Laboratory analysis report from Pace Analytical for a site sample related to the Education Department project.

Similar indexed content