Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical__________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC
Client's Sample ID ATC-1220-89M-DX2
Lab Sample ID 103233904
Filename F11228B_04
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 12/20/2001
ICAL Date 11/19/2001 Received 12/21/2001
CCal Filenamejs) F11228B_01 & F11228B_16 Extracted 12/23/2001
Method Blank ID BLANK-1389 Analyzed 12/28/2001 23:51
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
0.0028 A 2,3,7,8-TCDF-13C 2.00 61
a 2,3,7,8-TCDF
Total TCDF
ND
ND 0.0020 2,3,7,8-TCDD-13C 2.00 74
sJ 1,2,3,7,8-PeCDF-13C 2.00 65
2,3,7,8-TCDD ND 0.0021 A 2,3,4,7,8-PeCDF-13C 2.00 66
Total TCDD 0.0043 0.0020 J 1,2,3,7,8-PeCDD-13C 2.00 81
1,2,3,4,7,8-HxCDF-13C 2.00 73
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 77
2,3,4,7,8-PeCDF ND 0.0100 2,3,4.6,7,8-HxCDF-13C 2.00 74
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 74
1,2,3,4,7,8-HxCDD-13C 2.00 89
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 91
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 80
1,2,3,4,7,8,9-HpCDF-13C 2.00 78
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 94
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 64
2,3,4,6.7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3.4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7.8-TCDD-37CI4 0.20 75
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.0320 0.0100 J
1,2,3,4,6,7,8-HpCDF 0.0150 0.0100 J Total 2,3.7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00070 ng/m2
Total HpCDF 0.0150 0.0100 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0340 0.0100 J
Erl Total HpCDD 0.0670 0.0100 J
OCDF ND 0.0200
OCDD .0.2100 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,e-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis • = See Discussion
Report No.... 01-1052540
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003474159