TEM asbestos (air) TRC, 2002, 41 sample

Machine-extracted title · confidence 48%

TEM asbestos analysis report for air sample from TRC job 202011870, Lab Sample 41.

NYC-WTC_000246302–000246316
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TEM Asbestos (air) Count Sheet sample area analyzed

Client Name: TRC Environmental Corporation loll#: 202011870 Volume (liters): 1 505.5 Lab Sample #: 49 Filter Type/Filter Area: MCE 385 nim2 Client Sample #: SNOl 102ASBAIR0303 Grid Opening Size: 0.01000 Received: 01/12/2002 09:41:24 Area Examined: 0.06000 mm2 Date Analyzed: 01/14/2002 Magnification: 20,000 Scope #: Accelerating Voltage: 100 KeV Analysis Performed by: Mikhail Gruzman Grid Length Width Orient. SAED Photo Location Opening Fiber flM /iM Fiber Type Morphology EDS

E5-C4/1 1 NSD □ E5-E4/1 2 NSD U E5-E4/1 3 NSD U E5-F4/1 4 NSD U E3-G4/1 5 NSD U A6-H4/1 6 NSD u

NSD; No Asbestos Structures Detected Conunents Structure Density Concentration Total Grid Openings: 6 (str/mm2) (str/cc air) Grid Evaluation Chrysotile Asbestos Structures: 0 <16.7 <0.0043 13 Grid Openings Covered > 50% Amphibole Asbestos Structures: 0 <16.7 <0.0043 S Intact Grid Opening > 50% Asbestos Structures >=5 microns: 0 <16.7 <0.0043 S Undissolved Filter < 10% Total Non-Asbestos Structures: Folded Replica < 50% Total Asbestos Structures: 0 <16.7 <0.0043 13 Filter Loading < 10% 1434 Analvtical Sensitivity; 16.7 0.0043 13 Particulate Even

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT 2008 CITY_21MC100_014658938

NYC-WTC_000246310

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000246310Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →