Characterization of the Dust/Smoke Aerosol that Settled East of the World Trade Center (WTC) in Lower Manhattan after the Collapse of the WTC n September 2001 Paul J. Lioy/'^ Clifford P. Weisel,''-^ James R. Millens,^ Steven Eisenreich,' ’* Daniel Vallern,^ John Offenberg/ Bfiark Buckley,’ Barbara Turpin,Miauhua Zhong,Mitchell D. Cohen,^ Colette Prophete,^ III Yang,’ Robert Stiles,’ Glen Chee,^ Willie Johnson,’ Robert Porcja,’-'’ Shahnaz Alimokhtari,’ Robert C. Hale,^ Charles Weschler,’ and Lung Chi Chen^ ^Environmental and Occupational Health Sciences Institute of New Jersey, UMDNJ-Robert Wood Johnson Medical School and Rutgers University, New Brunswick, New Jersey, USA; ^Department of Environmental and Community Medicine, UMDNJ-Robert Wood Johnson Medical School, New Brunswick, New Jersey, USA; ^MVA, Norcross, Georgia; ^Department of Environmental Sciences, Rutgers University, New Brunswick. New Jersey, USA; ^National Exposure Research Laboratory, U.S. Environmental Protection Agency. Research Triangle Park. North Carolina. USA; ®Nelson Institute of Environmental Medicine, NYU School of Medicine, New York, New York, USA; ’Department of Environmental Sciences, Virginia Institute of Marine Science, College of William and Mary, Gloucester, Virginia, USA

sample was taken on day 6 (17 September The explosion and collapse of the World Trade Center (WTC) was a catastrophic event that pro­ 2001) after the terrorist attack. The purposes duced an aerosol plume impacting many workers, residents, and commuters daring the first few for collecting the samples were a) to deter­ days after 11 September 2001, Three bulk samples of the total settled dust and smoke were col­ mine the chemical and physical characteris­ lected at weather-protected locations east of the WTC on 16 and 17 September 2001; these samples tics of the material that was present in the are representative of the generated material that settled immediately after the explosion and fire and dust and smoke that settled from the initial the concurrent collapse of the two structures. We analyzed each sample, not differentiated by parti­ plume, and b} to determine the absence or cle size, for inorganic and organic composition. In the inorganic analyses, we identified metals, presence of contaminants that could affect radionuclides, ionic species, asbestos, and inorganic species. In the organic analyses, we identified acute or long-term human health by inhala­ polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls, polychlorinated dibenzodiox­ tion or ingestion. It was anticipated that the ins, polychlorinated dibenzoftirans, pesticides, phthalate esters, brominated diphenyl ethers, and actual compounds and materials present in other hydrocarbons. Each sample had a basic pH. Asbestos levels ranged from 0.8% to 3.0% of the the plume would be similar to those found mass, the PAHs were > 0.1% of the mass, and lead ranged from 101 to 625 pg/g. The content and in building fires or implosion of collapsed distribution of material was indicative of a complex mixture of building debris and combustion buildings. The primary differences would be products in the resulting plume. These three samples were composed primarily of construction the simultaneous occurrence of each type of materials, soot, paint (leaded and unleaded), and glass fibers (mineral wool and fiberglass). Levels of event, the intense fire (> l,000‘’C), the hydrocarbons indicated unbumed or partially burned jet fuel, plastic, cellulose, and other materials extremely large mass of material (> 10 x 10^ that were ignited by the fire. In morphologic analyses we found that a majority of the mass was fibrous and composed of many types of fibers (e.g., mineral wool, fiberglass, asbestos, wood, paper, and cotton). The particles were separated into size classifications by gravimetric and aerodynamic Address correspondence to P.J. Lioy. Exposure Measurement and Assessment Division, methods. Material < 2.5 pm in aerodynamic diameter was 0.88-1.98% of the total mass. The Environmental and Occupational Health Sciences largest mass concentrations were > 53 pm in diameter. The results obtained from these samples can Institute, 170 Frelinghuysen Road. Piscatasvay, NJ be used to understand the contact and types of exposures to this unprecedented complex mixture 08854-8020 USA. Telephone; (732) 445 0150. Fax: experienced by the surviving residents, commuters, and rescue workers directly affected by the (732) 445 0116. E-mail: [email protected] plume from 11 to 12 September and the evaluations of any acute or long-term health effects from We thank D. Bates and his analytic team in the rcsuspendable dust and smoke to the residents, commuters, and local workers, as well as from the U.S. EPA’s Kansas City Regional Laboratory for their analysis of the dust for dioxins and furans. Wc materials released after 11 September until the fires were extinguished. Further, these resulu sup­ also thank C. Schopfer of the Environmental and port the need to have the interior of residences, buildings, and their respective HVAC systems pro­ Occupational Health Sciences Institute (EOHSI) fessionally cleaned to reduce long-term residential risks before rehabitation. Key woriis-. aerosol, for completion of the radionuclide analyses; R. inorganic components, morphologic characterization, organic components. World Trade Center. Harrington for analytic support, and M.J. Environ Health Perspeet 110:703-714 (2002). [Online 4 June 2002] La Guardia of the Virginia Institute of Marine http.-l/ehpnetl.niehs. nih.gov/eiocs/2002H } 0p703-71-Hioylabslraet.html Science for technical assistance. Wc extend our grat­ itude to D. Owuor for assistance in the preparation of this manuscript. Finally, we express our deepest sympathy and continuing concern for the families The 11 September 2001 attack on the World to the WTC site, and the dust and smoke of the victims, and survivors of 11 September 2001. Trade Center (WTC) in New York City settled at many outdoor and indoor loca­ This work was funded in part by supplemental (NYC) resulted in an intense fire and the tions. From the first hours to 18 hr after the funds from the National Institute of Environmental subsequent complete collapse of the two collapse, the winds transponed the plume to Health Sciences (NIEHS) to the NIEHS Centers at main structures and adjacent buildings. It EOHSI (ES05022-12) and the NYU Institute of the cast (Figure 1) and then to the southeast Medicine (ES00260). NYU is also funded in part also led to significant damage to many sur­ across and beyond Brooklyn, New York. by a U.S. Environmental Protection Agency (EPA) rounding buildings within and around the To begin assessing the exposure to dust PM Center Grant (R827351)- P J Lioy was also WTC complex. The 16-acre area has become and smoke among the residential and com­ supported in part by a U.S. EPA University known as Ground Zero. A consequence of muter population during the first few days, Partnership (CR827033). tbie pulverization of buildings and the fires samples of particles that initially settled in This work has been subjected to agency review was the development of a large plume of dust downtown NYC were taken from three un­ and approved for publication. Mention of trade names or commercial products does not constitute and smoke that released both particles and disturbed protected locations to the east of endorsement or recommendations for use. gases into the atmosphere. The initial plume the WTC site. Two samples were taken on Received 15 January 2002; accepted 8 April impacted all directions immediately adjacent day 5 (16 September 2001) and the third 2002.

■Environmental Health Perspectives • volume 1101 number 7 I July 2002 703

CITY_21MC100_013449756 NYC-WTC_000246025

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000246025Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →