NYC-WTC_000383974
ATC IAQ measurements conducted January 11, 2002 at P.S. 89M for NYC BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Indoor air quality measurements at P.S. 89M; January 2002.
NYC-WTC_000245280–000245283OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Real-Time Environivien tal Measurements
ATC collected sixty-one (61) sets of real-time environmental measurements consisting of sixty (60) in the school building and one (1) outdoors. All five floors of the school were surveyed. These results are described below. Field data sheets are found in Attachment 1.
Temperature
Indoor dry bulb temperature measurements ranged fom 68.3 °F to 92.0 °F. Seven (7) measurement.s were above the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). These measurements were collected from 5^'’ floor. The outdoor temperature was 56.5 °F.
Re/ative Humidity
The relative humidity indoors ranged from 19.5 percent to 29.7 percent. All measurements were below the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity was 18.8 percent.
Carbon Dioxide CanceJ^tration
Carbon dioxide concentrations indoors ranged from 416 ppm to 540 ppm. All CO? measurements were below the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentration was 448 ppm. Therefore, the maximum acceptable level of CO? at this location was 1148 ppm (background level + 700 ppm). Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration. The school building during ATC’s assessment was not occupied.
Carbon Monoxide Concentr^on
Carbon monoxide concentrations indoors were 1-2 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm The outdoor CO concentration was 3 ppm-
Respirable Particulates (PM2_j}
Respirable particulate concentrations* indoors ranged between 6 pg/m^ to 18 pg/m^. All measurements were below the NPAAQS of 65 pg/rn^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter The outdoor respirable particulate concentration was 36 pg/m^.
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
CONFIDENTIAL, CITY_21MC100_003471671 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000245282
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000383974
ATC IAQ measurements conducted January 11, 2002 at P.S. 89M for NYC BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400542
IAQ report for PS 89M with January 2002 measurements and BOE involvement.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245292
Notes and results from IAQ measurements at P.S. 89M; January 2002.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400554
IAQ report detailing measurements collected January 15, 2002 at PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000325964
Indoor air quality measurements at PS 89M, Jan 2002, school environment.
14 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401484
Indoor air quality measurements collected December 12, 2001 at Stuyvesant High School.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000255543
Indoor air quality measurements collected on December 13, 2001 at the referenced school.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273973
Memorandum regarding indoor air quality measurements at Stuyvesant High School.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311194
ATC report of indoor air quality measurements at Stuyvesant High School (M477).
12 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401541
IAQ measurements reported for December 24, 2001 at Stuyvesant High School.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000255539
ATC IAQ report of measurements collected December 12, 2001, at Stuyvesant High School.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237001
Letter from ATC Associates to NYC Board of Education reporting indoor air quality measurements at P.S. 89M collected on January 14, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000383974
ATC IAQ measurements conducted January 11, 2002 at P.S. 89M for NYC BOE.
Similar indexed content
NYC-WTC_000400542
IAQ report for PS 89M with January 2002 measurements and BOE involvement.
Similar indexed content
NYC-WTC_000245292
Notes and results from IAQ measurements at P.S. 89M; January 2002.
Similar indexed content
NYC-WTC_000400554
IAQ report detailing measurements collected January 15, 2002 at PS 89M.
Similar indexed content
NYC-WTC_000325964
Indoor air quality measurements at PS 89M, Jan 2002, school environment.
Similar indexed content