NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/21/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction iSAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Prcject/Site: New Stuyvesant K.S., 345 Chambers St., NY, NY TEM Sample Ko.: 5735 61727
Various Site.s Inside and Outside the Building
Date Received:lC/2 02 0i Grid Openings Analyzed;__ 4
Project Sample No.:__13. Average Grid Opening: 106.00 urn
Air Volume: 1944 liters Total Area Analyzed:0;0£50 jTir^
Filter Type: MCE 25 mm diani.. Pore Size: 0.45 urn Analytical Sensitivits': 22.2 s/mm2
Effective Areb: 385 mm2 C . 0044 s/oc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct - Filter Air
Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/co ngm/m3
Chrysotilis Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0
Amphibole Asbestos 0 0 0 0 0 C.0 0.0000 0
Ambiguous C 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 C
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 C 0 0 0 0 0.0 0 .0000 N/A
Totals (All Structures) 0 0 0.0 0 . 0000 N/A
The estimated uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber" i.d. (EDS/SAED) : None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Ancilyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy