NYC 9/11 Public Portal Document
protocol prior to placement on newly installed carpeting, and a second time as part of the capital
cleaning program, which also followed a specific wet-wipe protocol.
TRC also sampled soft goods, such as cloth chairs, couches, fabric wall partitions. None of the
thirty-one (31) samples exceeded the individual sample post-cleaning target and the geometric
mean was less than 1,000 str/cm^. Twenty-two (22) samples were found to be below the
analytical detection limit. Although results indicated that no action was required, all fabric based
chairs, couches and fabric partitions were steam cleaned.
TRC sampled internal components of computers and copiers. This involved the partial
disassembly of computers and copiers prior to sampling. Thirty (30) samples were collected and
analyzed. Four of the thirty samples exceeded the post cleaning target concentration and the
geometric mean target concentration was exceeded. All computers, monitors, printers, copiers
and fax machines have been removed from the NYCLD space and replaced.
TRC sampled boxed items, such as files, papers, personal effects, in offices and general areas.
Twenty-five (25) samples were collected and analyzed. None of the twenty-five (25) samples
exceeded the post cleaning target concentration and the geometric mean target concentration was
not exceeded. Twenty-two (22) of the twenty-five (25) samples were found to be below the
analytical detection limit.
HVAC System
The primary components of the HVAC system include the supply ductwork, return ductwork, air
handling unit, and ceiling return plenum. Each of these components was sampled for asbestos in
surface dust following ASTM microvacuum techniques. TRC sampled the HVAC system after
the system was cleaned by ZAR’s initial HVAC cleaning contractor, G & G. Results of HVAC
sampling, presented in Appendix A, are organized as follows;
Table 2a - Supply Ducts
Table 2b - Return Ducts
Table 2c - Air Handling Units
Table 2d - Induction Units
Table 2e - Ceiling Return Plenum
14
CITY_21 MCI 00_014587235
NYC-WTC_000243822
OCR can misread numbers and units. Confirm readings against the page image before using them.