Machine-extracted title · confidence 40%

HVAC-related microvac sampling results for 100 Church Street project.

NYC-WTC_000243764–000243777
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 1c HVAC • Surface Dust Asbestos Microvac (ASTM 5575) Air Handlers New York City Law Department s 100 Church Street New York

I • Sample ID; MV21SAH15 MV21SAH11 MV21SAH' 0 MV21SAHQ8 MV >1SAH07 MV21SAH14 MVZ1SAH01 MV07SAH02 MV07SAH03 MV07SAH04 MW0604 MW0504 MW0404 Lab Sample ID: 1 2 4 5 6 7 9 11 12 13 15 16 17 Sample Date: 1/21/02 1/21/02 1/2lj'O2 1/21/02 1/21/02 1/21/02 1/2 i/02 1/21/02 1/21/02 1/21/02 1/21/02 1/21/02 1/21/02 * Sample Type: Microvac Microvac Microvac Microvac Microvac Microvac Microvac Microvac Microvac Microvac Microvac Microvac Microvac Floor 21 21 21 • 21 21 21 7 7 7 6 5 4 Air handler Air handler Air hand er Air handler /ilr handler Air handler Air ha idler Air handier Air handlei Air handler Supplemental supply 15, supply 11, supply 0 supply 08, : upply 07. supply 14, suppl rOI. supply 02, supply 03 supply 04, Supplemental supply ail mixing mixing mi)(i ig mixing ; mixing mixing m Xing mixing mixing mixing supply ail handler, duct chamber floor, chamber floor, chamber flo >r, chamber floor. charter floor, chamber floor. chamber oor, chamber floor. chamber floor chamber floor. Supplemental handler, in word base of cooling base of cooling base of coo I ig base of cooling base of cooling base of cooling base of cO' )ling base of cooling base of cooling base of cooling supply air cafeteria neout processing Location; coils coils co is coils coils coils :oil5 coils coils coils handler of A/C room area

CONSTITUENTS

ASBESTOS {structures/cm^} 1,070 47,080 <1.070 3,210 1,070 <535 51 360 36.380 36,380 38,520 1,605 <535 535

* Post Cleaning Target = <10,000 str/cm2 (structures per square centimeter). < = less than

H H

!l

Q

O O

-P* CT 00 me Cusfomer-Focused Solutions

!

NYC-WTC_000243766

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000243766Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243624

Table of HVAC-related microscopy results (ASTM 5575) for NYC Law Department project 35052-0000-00002.

Similar indexed content

HVAC sampling report, TRC 2002

NYC-WTC_000243865

Industrial hygiene report of HVAC samples analyzed by TRC for NYC Law Department.

Similar indexed content

NYC-WTC_000436122

Lab report with sample IDs and floor locations for asbestos analysis at City Law Department facility.

Similar indexed content

Compare copies and versions →