NYC 9/11 Public Portal Document
NYCLD Space
TRC performed asbestos surface dust sampling on floors 2 through 6 and 20 following cleaning
activities conducted by ZAR’s cleaning contractors. Surface dust samples were collected on
many surfaces within the space. Results, which are presented in Appendix A, are organized as
follows:
Table la - Carpet
Table lb - Top of Perimeter Induction Units
Table Ic - Hard Surfaces
Table Id— Soft Goods
Table le - Computer/Copier Equipment
Table If-Boxed Items
Table Ig - Field Blanks
A total of one hundred and nineteen (119) samples were collected and analyzed for asbestos in
surface dust via ASTM 5755 microvacuum method. A post cleaning target concentration of less
than 10,000 structures per square centimeter (sirem’) for all samples and a geometric mean
concentration of less than 1,000 str'enr for each data set was established. In calculating the
geometric mean, one-half of the sample detection limit was used in the calculation for samples
found to be below the analytical detection limit.
Carpet results indicated that three (3) of the ten (10) samples collected were in excess of the post
cleaning target concentrations. The carpet has since been removed and replaced with new
carpeting.
Results of sampling the tops of the perimeter induction imits indicated that one (1) of the seven
(7) samples was in excess of the post cleaning target and the geometric mean was slightly higher
than the 1,000 target geometric mean. These areas have since been re-cleaned and all induction
units have been painted.
TRC sampled hard surfaced items such as desks, bookshelves, file cabinets, floors. None of the
twelve (12) surface samples exceeded the post cleaning target concentration. Nine (9) of the
twelve (12) samples were less than the analytical detection limit. Although results indicated no
action was required, all furniture was re-cleaned twice, once according to a defined wet-wipe
13
CITY_21 MC100_014587095
NYC-WTC_000243718
OCR can misread numbers and units. Confirm readings against the page image before using them.