NYC 9/11 Public Portal Document
4.5.5 Polychlorinated Biphenyls
Seven (7) air samples were collected and analyzed for Polychlorinated Biphenyls (PCBs).
Results of PCB air sampling are presented in Table 14 of Appendix A. A review of the data
indicates that all of the results were below the analytical detection limit for PCBs.
4.5.6 Mercury
Seven (7) air samples were collected and analyzed for mercury. Results of mercury air sampling
are presented in Table 15 of Appendix A. A review of the data indicates that all of the results
were below the analytical detection limit for mercury.
4.5.7 Respirable Particulates
Eighteen (18) air samples were collected and analyzed for respirable particulates. Results of
respirable particulate air sampling are presented in Table 16 of Appendix A. A review of the
data indicates that all of the results, except one air sample, were below the analytical detection
limit for respirable particulates. The air concentration of respirable dust for the one air sample
where dust was detected was much lower than 5.0 mu/m\ the OSHA PEL.
4.5.8 Respirable Silica Quartz
Eighteen (18) air samples were collected and analyzed for respirable silica quartz. Results of
respirable silica quartz air sampling are presented in Table 17 of Appendix A. A review of the
results indicate that all of the results were below the analytical detection limit for respirable silica
quartz.
4.5.9 Dioxins [ Change to picograms to match Table 18J
Seven (7) air samples were collected and analyzed for dioxins. Results of dioxin air sampling
are presented in Table 18 of Appendix A. The results indicate that concentrations ranged from
0.0164 to 0.0856 picograms per cubic meter (pg/m3) expressed as 2,3,7,8 tetrachlordibenzo-p-
dioxin (TCDD) toxicity equivalents (TEQ). The TEQ essentially sums the relative toxicities of
each of the forms of dioxin found relative to TCDD, the most toxic form of dioxin. All results
were well below the NIOSH limit of 10,000 fg/m3. In addition, these results were incorporated
23
CITY_21 MC100_014586896
NYC-WTC_000243590
OCR can misread numbers and units. Confirm readings against the page image before using them.