Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
4.4.4 Total Particulate Matter Samples and Results
Twenty-eight (28) samples were collected from inside computers and related equipment and
analyzed for total dust. The results of this sampling are presented in Table 8 in Appendix A.
Samples were collected of dust present inside the computers to deteimine the extent of dust
accumulation. A sample was also collected from a TRC West 29'' Streel New York office
computer to represent background control concentration of dust present in a computer. As can
be seen from Table 8, only one sample was found to be higher than the control sample taken
from TRC’s office.
Sampling Methodology
Sampling was conducted utilizing a 37-millimeter filter cassette with a 5 micron PVC filter
attached to an air sampling pump. A short piece of tygon tubing was attached to the end of the
cassette to microvacuum a measured surface area to collect dust present on the internal computer
components. Analysis of the filter was via gravimetric analysis following NIOSH Sampling and
Analytical Method 0500.
4.4.5 Dioxin Wipe Sampling and Results
Table 9a in Appendix A presents the sampling and results for dioxin. Dioxins were detected in
low concentrations in fourteen (14) of the twenty (20) wipe samples collected. TRC
incorporated these results into a site specific human health risk assessment to determine the risk
associated with the concentrations found at 100 Church Street. TRC conducted this risk
assessment following United States Environmental Protection Agency (USEPA) protocols. A
conservative, that is a highly protective, estimate of risk of cancer associated with the dioxin
wipe and air concentrations was found to be 8.5E-07 (or 8.5 in ten million) which is less than
(i.e., better than) the target cancer risk level of one in one million. The human health risk
assessment calculations and assumptions can be found in Appendix B of this report.
These results notwithstanding, the NYCLD space was re-cleaned in an effort to remove any
residual dioxin from surfaces. As each floor is re-cleaned, TRC is resampling surfaces for
dioxin.
19
CITY_21 MC100_014586892
NYC-WTC_000243586
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000243586Source: NYC Law Department, mirrored locally