NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 36 pages

Stuyvesant High School indoor air study, 2002

Machine-extracted title · confidence 39%

Executive summary of DOH BOE indoor air study at SHS; sample results referenced.

NYC-WTC_000243060–000243095
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Stuyvesant Analysis Final Draft; For Internal NYC DOH Only, 2/8/2002, 10:44 AM

Daily Rate ofHeadache, Respiratory, Skin, Eye, and Throat (HRSET) Complaints and Average Daily PM2.5 Figure 4 presents the daily rate of headache, respiratory, skin, eye and throat complaints relative to average daily PM2.5 measurements. PM2.5 remained below 40 pg/m^ through October 19* increasing to 60.4 pg/m^ on October 22"** and reaching the peak value on October 23"^“ of 81.8 pg/m^ decreasing to 57.8 pg/m’ on October 24* . PM2.5 continued to decrease through October 26* at which point the average daily PM2.5 began to increase but still remained below 40 pg/m^ through October 30* . The daily rate of HRSET complaints remained below 2 complaints per 1000 students on October 15* . The next day, October 16 the complaints rose to 2.4 per 1000 students and by October 17* the daily rate of complaints per 1000 students reached the first peak for the study period of 4.4 per 1000 students. The HRSET complaint rate dropped on October 19* to 3.2 per 1000 but peaked (for the last time during the study period) on October 22"‘’ After October 22"“ the daily rate of HRSET complaints reached a maximum of 2.7 on October 25* and October 29* .

There was a small negative linear correlation between HRSET and the daily PM2.5 averages (r = -0.2) which was not statistically significant (p >0.05).

B. CO2

Average Daily CO2 Indoors and Outdoors Indoor and outdoor CO2 daily averages are presented in Figure 5. Outdoor CO2 daily averages were consistently lower than inside averages. The indoor averages ranged from 686.2 (ppm) to 947.1 (ppm), and the outdoor averages ranged from 329.0 (ppm) to 423.5 (ppm). Further, the outdoor daily averages exhibited fewer peaks than the indoor daily averages.

The correlation coefficient between indoor and outdoor CO2 was 0.6 and was statistically significant (p<0.01).

Daily Rate ofHeadache and Average Daily CO2 Levels Figure 6 presents the daily rate of headache and average daily CO2 levels. As can been seen the number of headache complaints per 1000 students remains below 2 through October n*, increasing to a high of 2.7 per 1000 on October 18“’ and decreasing to 1.4 per 1000 on October 19“*. For the remaining days in the study period, the daily rate of headaches is below 2 headaches per 1000 students except for October 29* in which the rate of headaches increased to 2.4 but then decreased to 1.4 reported headaches per 1000 students the following day. The daily average CO2 level remained below 850 ppm through October 19*, increasing to 947.1 ppm on October 22.

17

NYC-WTC_000243076

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000243076Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000245464

Permit application unrelated excerpt; contains mayoral report and NYC identifiers; likely overarching documents for school-related permit.

Similar indexed content

NYC-WTC_000277292

Memo reviewing PM2.5 data from Stuyvesant High School air quality testing.

Similar indexed content

NYC-WTC_000138069

Archival folder label for Health Department biweekly reports related to World Trade Center activities from 2000 to 2001.

Similar indexed content

Compare copies and versions →