Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Lead
Tier Action Lead (settled dust) Lead (indoor air)
Level Basis Level Basis
I Aggressive >40 ug/fe 1) HUD standard >1.5 ug/nL NAAQS
cleaning. If levels for floors (intended to
persist, take 2) Residential keep 99.5% of
additional action to Lead Hazard children below
reduce exposure. Standard (TSCA 30 ug/dl)
Section 403)
n Maintain 40 ug/ft" to 25 25 ug/ft^ is HUD 1.5 ug/m’ to 0.1 ug/m3 is
recommended ug/ft^ (or screening level 0.1 ug/m^ (or UBK Lead
cleaning methods. background) for floors background) Model default
Consider additional value for urban
monitoring. background
ni No further action <25 ug/ft^ (or Level could also 0.1 ug/m’ (or Level could also
background) be set at that background) be set at that
found in found in
background, or background, or
unaffected, areas, unaffected,
so that no areas, so that no
increase in risk increase in risk
due to lead due to lead
would be would be
expected. expected.
13
NYC-WTC_000242786
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000242786Source: NYC Law Department, mirrored locally