107 Haddon Avenue EMSL EMSL Analytical, Inc,- Westmont, NJ. 0S108 (856) 858-4800 ▼ 1/7/02 Attention: U.S.BPA HQ Financial Services Division 1200 Pennsylvania Avenue NWMaildiop2734R Washington, DC. 20460

Project: Residential Sampling Ref. Number; 360100679

Silica Analysis Performed by Method NIOSH 7500 Crystalline Particle Analysis Performed by X-Ray Diffraction (XRD)_________ Nuisance Dust Airborne Particu/eac Sample Sample Artaiytc AnuKyte % .^naJyticnl Weight Cone. Weight Cont .Analyte Sensithtty Sample ID Identification Analjle ID Volume (ntg) (mg/in’) (mg) (mc/m’) (mg/m’) (L)

tR]BRF-A-1S Qa-iriz 0 0.013 N/A <a(»< ri/A N/A N/A Cristobalite <1012 N/A N/A Tridymite W/A r4/A N/A Calcite <0.004 N/A N/A Portland/ Lime 0,020 N/A N/A Gypsum 0.004 N/A N/A Mica O011 f4/A N/A Halils 0.006 N/A N/A FiDrous Glass ND N/A

[H1BRF-&.15 Quart? 0 0,054 N/A <0.004 N/A N/A N/A CriEiobalito <0.012 N/A N/A T ridymHe W/A N/A M/A Qalclle 0.004 N/A N/A Portland/ Lime <J.020 N/A N/A Gypsum 0.004 N/A N/A Mica <0.011 rj/A ZJ/A Haihe <0.006 N/A N/A Fibrous Glass A/D N/A

(R]BTF-A-15 Quartz 0 A N/A <0.004 rvA N/A N/A Crislobalita <0.012 rJ/A N/A Tr’riymilG N/A t'l/A N/A Calcite <0.004 rj/A N/A Portland/ Lime <0.020 I’J/A N/A GypEum <0,004 rvA N/A Mica <0.011 U'A N/A Halite <0.006 n/A N/A f=ibmus Class ND N/A Pibmus GJQSi Risutis af» in pertnjbi'e M

John Newton J2 December, 200J .Ajtalj'St Date cf Analysis Di.rciaicncr: Tl)c liboralory c»n only verify die concentrations ofinilytcs on the (liter and not the final eoetenlratiotis doe to d'Li obUined by tion-l-iboratory personnel. In the absence <rfa. bulk dust sample, the specific form of crysiUJline silica Ciui not be detcrniined. Hcncc, dphuxjuartz, Ihcmcsi- prevalent fonn o’fcryst’iJlincsiJica, will be assumed. = )x« than.Ilie staled valu« The lowest reportable value is oquivalew to the Analytical Sensitivity which is calcuLited from the losvest reproducible uoncenlralionol silica detectable by llic uistn.iiiicnt. AIH.A ,Accrciiitcd - Laboratory ID 1/100192

CONFIDENTIAL, CITy_21MC100_003434258 SUBJECT TO PROTECTIVE ORDER NO, 2, SEPT, 2008

NYC-WTC_000242755

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000242755Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →