Residential silica analysis report, NJ, Jan 2002

Machine-extracted title · confidence 28%

Silica analysis performed on residential samples; project titled Residential Sampling, tracing method MOSH 7500.

NYC-WTC_000242731–000242743
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

107Haddon Avenue LEMSU^EMSL Analytical, Inc.- Westmont, NJ. 08108 (856) 858-4800 1/10/02 Attention: U.S.EPA HQ Financial Services Division 1200 Pennsylvania Avenue NW Maildrop 2734R Washington, DC. 20460

Project; Residential Sampling Ref. Number: 360100619 Revision 120201

Silica Analysis Performed by Method NIOSH 7500 Crystalline Particle Analysis Performed by X-Ray Diffraction (XRD)________ Nuisance Dust Airborne Silica Sample Sample Silica Silica % Analjlical Sample ID Identification Particle ID Volume Weight Cone. Weight C<mc. Silica Sensitivity (mgl (mg/m’l (mg/m^) (mg/mb (L) [R]BTF-B-2 Quart 0 A N«A <0.004 C/lsioballts <0.012 Tridymite N/A Calcite <0.004 Pontend/ Lime <0.02 Gypsum <0.004 Mica <0.011 Halite <0,008 Fibrous Glass N/A

(R)BIF-A-2 Quartz Q A N/A co 004 Cristobalite 0.012 Tridymite N/A Calcite 0.004 Portland/ Lime <0.02 Gypsum <0.004 Mica <0.011 Halite <0.008 Fibrous Glass N/A

[R]BIF.B-2 Quartz 0 A N/A <0.004 Cristobalite <0.012 Tridymite N/A Calcite <0.004 Portland/ Lime <0.02 Gypsum <0.004 Mica <0.011 Halite <0.008 Fibrous Glass N/A

Jofm Nenton 21 November, 01 Analyst Date of Analysis Di.telaimcr. The laboraioty can only verity tbc eoacentration of silica on the Citer and not the final concentration due io data chained by liori-laboratoiy personnel. In die absence of a hulk dust sample, die specific form of crystalline silica can not be determined. Mence. alpha-guartz. the most prevalent form ofcrysullinc silica, will be assumed. = Ijzis than the S’atcd value The lowest rcporuble value is equivalent to the Analytical Sensitivity which is calculated from the lowesi reproducible concentration of silica delectable by the instrument. AIHA Accredited - Laboratory ID 1(100192

CONFIDENTIAL, CITY_21MC100_003434246 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000242743

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000242743Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →