Project: Residential
Ref. Number: 360100773
Silica Analysis Performed by Method NIOSH 7500
Crystalline Particle Analysis Performed by
X-Ray Diffraction (XRP)_________
Nuisance Dust Airbarne Particulate
Sample Sample Analyte Analyte % Aoalylical
Weight Cone. Vi'eight (pac. Analyte Sensitivity
Sample IO IdentiCcation Analyte ID Volume (mfi/m’) (mg/u?) (nigW)
(”>6)
(L)
Quartz 1317 0.09S 0.0729 <0.004 <AS N/A 0.0030
(R]TF-R1-32
Crtelooalte <0.012 <AS 0.0091
Tridymite N/A N/A N/A
Calcite <0.004 <AS 0.0030
Portland/ Lima <0.020 <AS 0.0152
Gypsum <0.004 -AS 0.0030
Mica <0.011 <AS 0.0084
Halite <0.006 <AS 0.0046
Fibmes Glass ND <AS 0.7594
[R11F.R1-32 Quartz 1316 0.040 0.0304 <0.004 <AS N/A 0.0030
Cristobalite ’X).012 <AS 0.DD91
Tridymite N/A N/A N/A
Caldte <0.004 <AS 0.0030
Portland/ Lime <0.020 <AS 0 0152
Gypsum <0,004 <AS 0,0020
Mica <0.011 <AS 0.00S4
Halite <0.006 <AS 0.0046
Fibrous Glass ND <AS o.7eoi
Quartz B2S A N/A «0.0D4 <AS N/A 0.0046
lRlRF-O-X-32
Cristobalite <0.012 <AS 0.0145
T ridymite N/A N/A N/A
Calcite «;o.oo4 <AS 0.0048
Portland/ Lime <0.020 <AS 0.0242
Gypsum <0.004 </LS 0.0048
Mica <0.011 <AS 0.0133
Halite <0.000 <AS 0.0072
Fibrous Glass ND <AS 1.2075
Fibioijs Ghse Pasu/TS sre pDf ctiDic
John Newton 20 December. 2001
Analyst Date of Analysis
Disclaimer: The leborarory can only verify the conoentranons ofanalytes on the Elter and not the final concentrations due to data obtained by
nop-Iaboraiory personnel. In Ihe absence of a bulk dust sample, the specific form of crystalline silica can not tw determined.
Hence, alplia-quaitz, the most prevalent form of ciysiallinc silica, uill be assumed. = Less than the stated value
The losvesi reportable value is equivalent to the Analytical Scnsitiviiy which i.s calculated from the lowest reproducible concentration of silica detectable bi' the iostrument.
AIHA Accredited - Laboratory 1D # 100192