NYC 9/11 Public Portal Document

I Jeanine Prudhorn sampiing plan v2.doc Page'91

Step 4.Define the Study Boundaries

There are a wide variety of routine and special human activities which might result in the generation of elevated levels of asbestos in breathing zone air. The activities selected for evaluation in this investigation are listed below:

1) Routine household activities (excluding active cleaning) 2) Active apartment cleaning (dusting, sweeping, vacuuming, etc.) 3) Simulated restoration (construction or demolition) activities that involve direct contact or handling of debris or dust.

Step 5.Develop a Decision Rule

The degree of similarity (or dissimilarity) of concentration values measured by personal air monitors and by fixed air monitors will be judged semi-quantitatively. The exact data evaluation procedure cannot be stated a priori, but it is expected that, for each type of activity investigated, a simple plot of the fixed station value (x-axis) versus the corresponding personal air value (y- axis) will reveal if there is a systematic pattern of differences between the two. For example, if the slope of the line is close to 1.0, it will be decided that there are no large and consistent differences, and that fixed air monitoring is adequate for assessing human exposure associated with the activity being considered. Conversely, if the slope of the line is substantially greater than 1.0, it will be concluded that fixed air monitors tend to underestimate personal exposures for individuals engaged in the specific activities investigated. In general, if significant differences exist between the two types of measurements, personal air samples will be judged to be most appropriate for assessing risks to individuals engaged in the activities, and data from stationary air monitors will be considered appropriate for individuals residing within the same apartment or working in the same location who may be passively exposed to the dust generated by the activity.

Step 6.Specify Limits on Decision Errors

With regard to the decision as to whether data from stationary air monitors are adequate for assessing personal exposure during some routine or special activity, the decision is semi- quantitative and no formal limit is unposed on decision error.

Step 7.Optimize the Design for Obtaining Results

Additional air samples or samples from different types of activities may be collected and incorporated into the study results as data become available on actual airborne exposure levels associated with specific types of activity. Samples collected on stationary or personal air monitors may also be analyzed for a variety of other environmental contaminants (e.g., metals, PCBs).

SECOND OBJECTIVE: PCM vs TEM

NYC-WTC_000241989

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241989Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →