duplicate or replicate samples.

Accuracy: Accuracy is a measure of the closeness of a sample analysis result to the "true" value. The accuracy of an analytical method is generally assessed by inserting a series of blind “performance evaluation” (PE) samples into the laboratory sample stream, where the “true” concentration of analyte in each PE sample is known. With regard to asbestos, PE samples are not available for most of the media being analyzed in this project, so accuracy will be determined primarily by an evaluation of agreement between repeat analyses, both within a laboratory and between laboratories.

Representativeness: Representativeness is the degree to which data accurately and precisely represent characteristics of a population, parameter variations at a sampling point, or an environmental condition. For this QAPP, representativeness is ensured by the selection of sampling locations in accordance with the sampling design requirements presented above.

Comparability: Data are comparable if collection techniques, measurement procedures, methods, and reporting units are equivalent for the samples within a sample set. These criteria allow comparison of data from different sources. Comparable data will be obtained by specifying standard units for physical measurements and standard procedures for sample collection, processing, and analysis. These requirements are specified in the attached SOPs for sample analysis procedures.

Completeness: Data are considered complete when a prescribed percentage of the total intended measurements and samples are obtained. Analytical completeness is defined as the percentage of valid analytical results requested. For this sampling program, a minimum of 90% percent of the planned collection of individual samples for quantification must be obtained to achieve a satisfactory level of data completeness.

Validation of QC Samples for TEM

Re-Analysis. All re-analysis samples (either different or same) will be validated by comparing the raw data sheets prepared by each analyst. The following acceptance criteria will be used to identify cases where results are not within acceptable limits:

Measurement parameter Acceptance Criterion

Number of fibers within each grid opening Must be the same Type of fiber Must be the same Fiber length 0.5 um or 10% (whichever is less stringent) Fiber width 0.1 um or 10% (whichever is less stringent)

NYC-WTC_000242012

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000242012Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →