NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 37 pages

NYC-WTC sampling plan draft, 2001

Machine-extracted title · confidence 46%

Draft ambient sampling protocol for WTC-related fiber and dust exposure assessments.

NYC-WTC_000241933–000241969
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

^ wtc residential plan octlS.wpd Page 25 I

J

****draft**** compromise between regulators and the regulated industry. An account of the politics and decision process leading to the selection of the 1% rule has been well described by Michael Moss and Adriarme Appel in an investigative report in the July 9, 2001 edition of the New York Times. Regardless of which account is most accurate or even if the two accounts actually emerged about the same time resulting in the final definition of asbestos containing material, neither account indicates that the derivation of the 1% rule was in a maimer that employed considerations of human health. The 1% rule is not based on health.

Two main short-comings of the 1% rule exist. * The 1% rule is not derived from a risk assessment or any other type of health based analysis. * The 1% rule does not insure that asbestos air levels will be at levels that are protective of human health.

The second point is not well documented in the literature. But two personal communications indicate this is a major problem with the 1% rule. OSHA (personal communication with Dan Krane, OSHA) has examined over 6000 work places in which asbestos existed in bulk material between 0% and 1 %. Four percent of these work places had asbestos air levels at or above the OSHA permissible exposure limit (PEL) of 0.1 f /cc. The measurements were point determinations and not 8 hour time weighted averages (TWA). But had the exposures continued for 8 hours, 4 % of the work places would have exceeded the PEL even though materials in these work places did not exceed 1% asbestos w/w.

The second indication of the limits of the 1% rule comes from Libby, Montana (personal communication with Chris Weis, EPA). Preliminary data from investigations into different types of activities show that tilling the soil in gardens with < 1% detectable levels of asbestos resulted in air levels close to the OSHA PEL.

Conclusion: The 1% rule has the advantage of being a legally enforceable level and precedence for its use is available. However the rule is not health based and may not provide adequate protection from airborne asbestos under a variety of conditions. Because of these limitations great care should be used in using any type of w/w percentage as guidance to protect human health. If percent determinations have to be made, they should be used only to confirm the presence or absence of asbestos or to recommend clean-up followed by further air testing. A possible guideline is suggested below.

Interpretation of bulk and air samples; The following table provides a general guide for determining public health actions based upon sampling of both bulk material and indoor air. The

25

NYC-WTC_000241955

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241955Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →