the amount of each source material suspended in air by the activity. Thus, the range of concentration and risk estimates based on either personal or stationary air samples could vary substantially from case to case. In general, when variability is wide, more samples are needed to support risk management decisions. The objective of this effort is to identify a variety of relevant exposure categories (i.e. apartments, apartment lobbies, commercial businesses, etc) and evaluate a representative number sites (8- 12) within each of these categories. If specific conditions associated with hazardous exposures are identified, this information can be communicated to the public and practical risk management decisions can be implemented (where necessary) to mitigate or abate unacceptable risks.

Step 4. Define the Study Boundaries

There are a wide variety of routine and special human activities which might result in the generation of elevated levels of asbestos in breathing zone air. The activities selected for evaluation in this investigation are listed below:

1) Routine household activities (excluding active cleaning) 2) Active apartment cleaning (dusting, sweeping, vacuuming, etc.) 3) Simulated restoration (construction or demolition) activities that involve direct contact or handling of debris or dust.

Step 5. Develop a Decision Rule

The degree of similarity (or dissimilarity) of concentration values measured by personal air monitors and by fixed air monitors will be judged semi-quantitatively. The exact data evaluation procedure cannot be stated a priori, but it is expected that, for each type of activity investigated, a simple plot of the fixed station value (x-axis) versus the corresponding personal air value (y-axis) will reveal if there is a systematic pattern of differences between the two. For example, if the slope of the line is close to 1.0, it will be decided that there are no large and consistent differences, and that fixed air monitoring is adequate for assessing human exposure associated with the activity being considered. Conversely, if the slope of the line is substantially greater than 1.0, it will be concluded that fixed air monitors tend to underestimate personal exposures for individuals engaged in the specific activities investigated. In general, if significant differences exist between the two types of measurements, personal air samples will be judged to be most appropriate for assessing risks to individuals engaged in the activities, and data from stationary air monitorswill be considered appropriate for individuals residing within the same apartment or working in the same location who may be passively exposed to the dust generated by the activity.

Step 6. Specify Limits on Decision Errors

With regard to the decision as to whether data from stationary air monitors are

CONFIDENTIAL, CITY_2IMCl00_009513610 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000241789

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241789Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →