Confidential WTC environmental monitoring draft

Machine-extracted title · confidence 41%

Draft confidential sampling and exposure monitoring plan for WTC debris events.

NYC-WTC_000241781–000241839
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

returned to acceptable levels.

This scenario will be carefully monitored by air sampling both in the vicinity of the simulated restoration activity and in the main living area of the apartment. These samples are described below.

Personal Air Monitor for Simulated Worker

The individual performing the simulated restoration will engage in simulated activities for a period of approximately one hour. This individual will wear a portable low-volume air sampling pump. Because it is expected that this activity will be associated with high airborne dust levels, the flow rate will be set at a low value (e.g., 0.5 L/min). If overloading does not occur, the entire sampling activity will be collected on one filter. If pilot studies suggest that 60 minutes of sample collection will result in filter overload, then a series of sequential samples will be collected (e.g., two 30-minutes samples or four 15-minute samples, etc.).

Fixed Air Monitor at the Work Area

One 3-hour air sample will be collected from the simulated work area before simulated restoration begins, and a set of three sequential 3-hour samples will be collected after the work is completed to monitor the time course of fiber disturbance and settling. The pre- and post-activity sampling will be done using a stationary high volume pump, placed in a convenient position within the work area that can be accessed by the sampling team without re-disturbing the dust. The flow rate for these pre- and post­ activity samples will be selected to yield a volume that meets or exceeds the minimum target volume specified in Appendix G without causing filter overload.

Stationary Air Monitor in the Main Business or Apartment

The stationary air sampler will be located in the main living area of the apartment or work area of the business. These samples will serve to measure the impact of the simulated restoration on “passive” air exposure at locations remote from the simulated restoration. In addition, these samples will serve as "clearance” samples to establish when the apartment or business is suitable for re-occupation by the owner or resident. Samples will be collected before, during and for three sequential time periods after simulated restoration work is completed. Pump flow rates will be set to ensure that a minimum volume of at least 1,200 L will be collected during each 3-hour sampling period (e.g., 7-8 L/min). Analysis of these samples will be done using the AHERA method (USEPA 1987). A property will be considered suitable for re-habitation if the final clearance sample complies with the AHERA standard or a more stringent standard, as directed by the NYC Department of Health. If the final clearance sample fails this standard, either more clearance samples may be collected, or alternatively, the pre-activity sample may be analyzed. In this case, the residence will be considered suitable for re-habitation if the final clearance sample does not have a fiber

CONFIDENTIAL, CITY_2IMCI00_009513619 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000241798

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241798Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →