NYC-WTC_000241981
Final NYC-WTC sampling plan documenting fiber exposure assessments.
19 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗Draft NYC-WTC environmental monitoring sampling plan for fibers and exposure.
NYC-WTC_000241745–000241780OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Allan Goldberg - Nyc-wtc sampling plan v2.doc Page 31
I
assigned, it extends beyond the analytical method or contractual compliance to protocols to address the overall technical usability of the generated data.
D2 . VERIFICATION AND VALIDATION METHODS
Data Verification ii
Data verification will include a review of the findings of all QA assessment activities (see Section C), including assessments of field collection procedures, sample labeling methods, chain-of-custody procedures, and all assessments of analytical data collection, recording and reporting. If any deviations are identified, the potential impact of those deviations on the reliability of the data will be assessed, and that information will be provided to the EPA Cii- Scene Coordinator and the Science Support Coordinator. I, Data Validation i' The data validation process consists of evaluation of all individual samples collected and analyzed to determine if results are within acceptable limits. These quantitative or qualitative limits of acceptability are defined for Precision, Accuracy, Representativeness, Comparability, and Completeness (PARCC), as discussed below.
Precision: Precision is defined a.s the agreement between a set of replicate measuremenl.s without assumption or knowledge of the true value. Agreement is expressed as either the relative percent difference (RPD) for duplicate measurements, or the range and standard deviation for larger numbers of replicates. Data on precision are obtained by analyzing duplicate or replicate samples.
Accuracy: Accuracy is a measure of the closeness of a sample analysis result to the "true" value. The accuracy of an analytical method is generally assessed by inserting a series of blind “performance evaluation” (PE) samples into the laboratory sample stream, where the “true” concentration of analyte in each PE sample is known. With regard to 1 asbestos, PE samples are not available for most of the media being analyzed in this project, so accuracy will be determined primarily by an evaluation of agreement between repeat analyses, both within a laboratory and between laboratories.
Representativeness: Representativeness is the degree to which data accurately and precisely represent characteristics of a population, parameter variations at a sampling point, or an environmental condition. For this QAPP, representativeness is ensured by the selection of sampling locations in accordance with the sampling design requirements presented above. 1
Comparability: Data are comparable if collection techniques, measurement procedures, methods, and reporting units are equivalent for the samples within a sample set. These criteria allow comparison of'data from different sources. Comparable data will be
NYC-WTC_000241775
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000241981
Final NYC-WTC sampling plan documenting fiber exposure assessments.
19 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
18 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436795
Draft NYC EH Environmental Monitoring chain-of-custody related to World Trade Center exposure tests.
19 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
19 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241781
Draft confidential sampling and exposure monitoring plan for WTC debris events.
19 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
19 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455886
Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
19 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
18 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000235065
Draft environmental sampling protocol for residential areas near the World Trade Center developed by ATSDR/DHAC in October 2001.
7 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418628
Draft NYC DOH environmental monitoring document relating to WTC collapse exposure fibers.
18 shared non-person entities · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
8 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164960
Draft compilation of asbestos air samples collected from residential areas November-December 2001 by NYC DOH and ATSDR.
13 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241781
Draft confidential sampling and exposure monitoring plan for WTC debris events.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
Similarity score 0.953 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442657
Draft quality assurance project plan for indoor environment impacts at WTC.
Similarity score 0.953 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
Similarity score 0.952 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442657
Draft quality assurance project plan for indoor environment impacts at WTC.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000241981
Final NYC-WTC sampling plan documenting fiber exposure assessments.
Similar indexed content
NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
Similar indexed content
NYC-WTC_000436795
Draft NYC EH Environmental Monitoring chain-of-custody related to World Trade Center exposure tests.
Similar indexed content
NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
Similar indexed content
NYC-WTC_000455886
Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
Similar indexed content