NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Air sampling for metals, PS 234M, 2002

Machine-extracted title · confidence 50%

Letter report detailing air sampling for metals at P.S. 234M in 2002.

NYC-WTC_000241633–000241634
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan July 3,2002 Air Sampling for Metals Page 2 P.S. 234(Manhattan) ATCProiectNoa5H9125:^279

Results

April 23

The metals that were found above the limits of detection were chromium (Cr) and lead (Pb). The other ten metals were not detected. Chromium was detected in the blanks.

Blank-correcting the Cr concentrations (blank average: 0.507 micrograms per filter) reduces them to below or just above4 the limit of detection. All Cr concentrations were below the EPA screening level.

Lead (pb) was detected in the sample (M2) from the floor hallway. The Pb concentration was 0.258 micrograms per cubic meter (0.258 ug/m’). This is below the EPA ambient air quality standard.

April 30

The metals detected on this date were Cr and manganese (Mn). Cr was detected in all four samples and the blanks. Blank-correcting the Cr concentrations of the samples (blank average 0.640 ug/filter) reduces them below or just above the limit of detection.

Manganese was detected in the roof sample (#M4) and in one of the blanks. Blank-correcting the Mn concentration of the sample (blank; 27.5 ug/filter) reduces the concentration to below the limit of detection.

These results indicate that the levels of these metals detected in the samples are trace contaminants of the filters and not significant constituents of the ambient air.

The Environmental Protection Agency (EPA) has set a screening level for hexavalent chromium (the more toxic form) in air of 0.6 micrograms per cubic meter of air (ug/m’), this assumes a continuous exposure for one year. These samples were analyzed for total chromium (trivalent and hexavalent).

The EPA’s ambient air standard for lead (Pb) is 1.5 ug/m’ (three-month average).

The EPA’s screening level for Mn is 0.5 ug/ m’.

ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.

Sincerely, ATC Associates, In

James R. Cohn, CIH, CSP Regional Manager, Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC100_003423145 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000241634

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241634Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →