NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Wipe samples for Dioxin, Stuyvesant HS, Jan 2002

Machine-extracted title · confidence 30%

ATC report of wipe-samples for PCDD/PCDF at Stuyvesant High School, Jan 2002.

NYC-WTC_000240899–000240901
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

February 4, 2002

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101 -4008

Re: Wipe Samples for Dioxin Stuyvesant High School 345 Chambers Street New York, New York ATC Project No. 15-19125-0246

Dear Mr. Orlan:

ATC Associates Inc. (ATC) is pleased to provide this report of the results of the wipe-samples for polychlorinated dibenzo-p-dioxins (PCDDs)and dibenzofurans (PCDFs) collected on January 9, 2002, at the referenced location. The New York City Board of Education (BOE) requested these samples to evaluate possible contamination in the school building per the recommendation of H. A. Bader, consultant to the parents association.

SCOPE OF WORK

Wagdi Abdelshahid, Industrial Hygienist of ATC’s New York City office, collected the samples on all three days.

The samples were collected using gauze pads and hexane as a solvent. The solvent was provided and samples were analyzed by Pace Analytical Services, Inc. (Pace) of Minneapolis, MN, a laboratory experienced in dioxin analysis. The analysis was performed by modified EPA Method 8290 using combined capillary column gas chromatography/high resolution mass spectrometry.

ATC’s findings and conclusions are based on the laboratory samples results and the conditions present in the school at the time of the assessment.

The sampling was performed consistent with generally accepted industrial hygiene practices. There were inherent limitations created by constraints of time, operational and work practice variability, variations in contaminant concentrations, and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates the samples were collected.

CONFIDENTIAL, CITY_21MC100_003432786 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240899

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240899Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000238245

Laboratory results for dioxins and dibenzofurans from wipe samples collected at Stuyvesant High School in January 2002.

Similar indexed content

NYC-WTC_000238242

Report on dioxin contamination evaluation at Stuyvesant High School based on January 2002 sampling.

Similar indexed content

NYC-WTC_000238248

Analysis results for dioxins and dibenzofurans from Stuyvesant High School collected in mid-January 2002.

Similar indexed content

Compare copies and versions →