TEM results summary, Stuyvesant H.S.

Machine-extracted title · confidence 57%

Summary of TEM results and statistical data for Stuyvesant H.S. project.

NYC-WTC_000240464–000240469
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/04/01

ASBESTOS FIBER liNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fibe:r Identification Oy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analvsis Parameters

Preject/Site: Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.; 5598 - 59982 Outside Buildiiig Date Received: 10/04/01 Grid Openings Analyzed;__4

Project Sample No.: 06 Average Grid Opening: 106.00 um

Air Volums: 1862 liters Total Area Analyzed: 0.0450 mml

Filter Ty-^e: MCE 25 mm diam. . Pore Size: 0.45. um Analytical Sensitivity: 22.2 s/mmZ Effective Area: 385 mm2 0.0046 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTOATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nqm/m3

Chrysotiltj Asbestos C 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Hon-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty cf this analysis is 1 standard deviation.

Non-assbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by;

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003432284 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240468

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240468Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293726

TEM analysis of New Stuyvesant HS samples; includes air volume and opening data.

Similar indexed content

Compare copies and versions →